Troubleshooting - cecotec CONGA POPSTAR 29600 AQUA&COLLECT Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 32
ENGLISH
Tips:
- When cleaning, be sure to take out the battery pack to avoid injury caused by accidental
start.
- If the device is not going to be used for a long time, install the sewage tank body, its upper
cover, the HEPA filter, the filter frame, the rolling brush body and the frame in the appliance
and place it in a ventilated place to dry and then for storage, so as to prevent the bad smell
caused by bacteria breeding due to the moist environment.
Regular maintenance and storage
It is recommended to clean the sewage tank, filters, rolling brush body and rolling brush cover
after each use.
When the sewage tank is full during use, it is recommended to immediately clean up, otherwise
it will affect the correct operation of the device.
When the filter is used for 30-50 hrs. (according to the use of the filter), it is recommended to
buy and replace the filter by contacting Cecotec, so as not to affect the performance of the
product.
If the product is not going to be used for a long time, it is recommended to pack the machine
according to the above steps, store it in a cool and dry place. Do not place it in direct sunlight
or in a humid environment.

6. TROUBLESHOOTING

Problem
The device does not work
Less vacuuming force
44
CONGA POPSTAR 29600 AQUA&COLLECT
Possible causes
1.
The product has no power or
insufficient power
2. The On/off button is not pressed
3. The rolling brush body is seriously
tangled
4. The machine stops working after
being turned on
1.
The sewage in the sewage tank has
reached the maximum capacity
2. The rolling brush cover and the
sewage tank are not installed in
place
3. The rolling brush body is entangled
with hair
4. The float filter is dirty
5. Insufficient battery power
Solution
1.
Charge the device
2. Press the On/off
button
3. Clean the rolling
brush body in time
4. Clean the sewage
tank
1.
Clean the sewage
tank
2. Re-install
3. Clean the rolling
brush body
4. Clean the filter
frame
5. Use the machine
after charging