Black Max BM903601 Guía De Referencia Rápida

Black Max BM903601 Guía De Referencia Rápida

Ocultar thumbs Ver también para BM903601:
Idiomas disponibles

Idiomas disponibles

Enlaces rápidos

WARNING:
This Quick Reference Guide is not a substitute for reading the operator's manual. To reduce the risk of injury or death, user must read and understand operator's manual before using this product. All page references refer to
the operator's manual.
IMPORTANT!
WARNING:
Using a generator indoors CAN KILL YOU IN MINUTES.
Do not connect to a building's electrical
Generator exhaust contains carbon monoxide. This is a
system unless the generator and transfer
poison you cannot see or smell.
switch have been properly installed and
the electrical output has been verified by
a qualified electrician. The connection
must isolate the generator power from
NEVER use inside a home
utility power and must comply with all
or garage, EVEN IF doors
applicable laws and electrical codes.
and windows are open.
TOOLS NEEDED
Socket Wrenches and an Adjustable Wrench
FIRST TIME ASSEMBLY
1
3
Install the feet (see page 11).
Raise the handle (see page 13).
Add entire bottle of lubricant provided to the gen-
4
erator (see page 13).
2
Install the wheels (see page 12).
BM903601/BM903631/BM903631CVNM QUICK REFERENCE GUIDE
1
Add fuel (see page 14).
NOTICE:
Do not use E15 or E85 fuel in this prod-
uct. It is a violation of federal law and will
damage the unit and void your warranty.
Only use OUTSIDE and
Only use unleaded gasoline containing
far away from windows,
up to 10% ethanol.
doors, and vents.
This is a 4-cycle engine. Do not mix fuel and
lubricant together.
Mix fuel stabilizer with gasoline according to
manufacturer's directions prior to filling the
tank.
2
Turn the fuel valve to ON (see page 14).
FUEL
VALVE ON
1
Press and hold the STOP switch until the engine stops. (See page 14.)
Turn the fuel valve to OFF before adding
lubricant.
Set unit on flat surface so engine is level.
Remove dipstick, wipe clean, put back in hole
(but don't screw in) and check lubricant level.
STARTING THE UNIT
3
Put choke lever in START position (see page 14).
CHOKE LEVER IN
START POSITION
Pull the recoil starting grip until the engine runs
4
(see page 14).
Allow engine to run for 15-30 seconds, then move
5
choke to RUN position (see page 14).
CHOKE LEVER IN
RUN POSITION
15-30 S
15-30 S
STOPPING THE UNIT
USING THE GENERATOR
Connect devices to be powered by generator by following the steps below (see pages 8-9).
1
• Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you
will power at the same time. See page 9 for how to calculate total amount of power needed.
• Start the generator with nothing connected.
• Plug in and turn on the first load, preferably the largest load you have.
• Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
• Plug in and turn on the next load.
• Again, permit the generator to stabilize.
• Repeat previous two steps for each additional load.
IMPORTANT: Never add more loads than the generator capacity. Take special care to consider surge loads in
generator capacity. (See pages 8-9.)
STORING THE UNIT
When preparing to store the generator, allow the unit to cool completely, then follow the guidelines listed on
1
1
page 18.
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Engine will not start.
No fuel.
Stale gasoline or water in gasoline.
Lubricant level is low.
Fuel valve is OFF.
Spark plug faulty, fouled, or improperly
gapped.
Choke lever is in RUN position.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
Dirty fuel filter.
CO sensor LED is flashing red, indicating a
CO hazard.
CO sensor LED is flashing yellow and/or
making an audible chirp, indicating a sensor
fault.
Engine hard to start.
Water in gasoline.
Weak spark at spark plug.
Engine lacks power.
Air filter element clogged.
Engine stored without treating or draining
gasoline, or refueled with bad gasoline.
AC receptacle does not work.
Circuit breaker is OFF.
Item plugged in is defective.
Generator makes a "spark knock" or "ping-
An occasional light "knocking" or "pinging"
ing" noise.
under heavy load is not a cause for concern.
However, if the knocking or pinging occurs
under normal load at a steady engine speed,
the problem may be with the brand of gasoline
being used.
If problem persists after trying the above solutions, contact customer service or a qualified service center for assistance.
NOTICE:
As the equipment owner, you are responsible for the performance of the required maintenance listed in the Maintenance section It is
recommended that you retain all receipts covering maintenance on your equipment. Neglecting or failing to perform the required maintenance
may increase emissions, decrease fuel efficiency, degrade performance, cause irreversible engine damage and/or void your warranty.
Make the most of your purchase! Go to
www.blackmaxtools.com and register your new tool
online. For questions about operating or maintaining
your product, please call 1-800-726-5760.
SOLUTION
Fill fuel tank.
Drain entire system and refill with fresh fuel.
Engine is equipped with Low Oil Shutoff. If
engine lubricant level is low, it must be filled
before unit will start. Check engine lubricant
level and fill, if necessary.
Turn fuel valve ON.
Replace spark plug.
Move choke lever to START position.
Drain fuel and carburetor. Refuel with fresh
gasoline.
Replace fuel filter or contact a qualified
service center.
Leave area immediately and relocate to an
open outdoor area. Ventilate area thoroughly
before occupying again. Ensure the generator
is located in an open outdoor area at least 20
feet away from all doors, windows, and oc-
cupied spaces, and point exhaust away from
occupied structures.
The CO sensor needs to be repaired or replaced.
Contact customer service or a qualified service
center for assistance.
Drain entire system and refill with fresh fuel.
Replace spark plug or contact a qualified
service center.
Check air filter element. Clean or replace as
needed.
Drain fuel and carburetor. Refuel with fresh
gasoline.
Turn ON the AC circuit breaker.
Try a different item.
Switch to a different brand of gasoline, making
sure that the octane rating is 86 or higher. If
problem continues, contact a qualified service
center.
998000170
1-28-20 (REV:02)
loading

Resumen de contenidos para Black Max BM903601

  • Página 1 BM903601/BM903631/BM903631CVNM QUICK REFERENCE GUIDE WARNING: This Quick Reference Guide is not a substitute for reading the operator’s manual. To reduce the risk of injury or death, user must read and understand operator’s manual before using this product. All page references refer to the operator’s manual.
  • Página 2 GUÍA DE REFERENCIA RÁPIDA DE BM903601/BM903631/BM903631CVNM ADVERTENCIA: Esta guía de referencia rápida no es un substituto para leer el manual del operador. Para reducir los riesgos de lesiones o muerte, el usuario debe leer y comprender el manual del operador antes de utilizar este producto. Todas las referencias a páginas se refieren al manual del operador.