TROUBLESHOOTING
Problem
Pump will not
1. Pump won't prime.
prime or retain
2. Suction lift too high.
prime after
3. Hose kinked.
operating.
4. Hose fitting not tight on inlet.
5. Air leak in suction hose.
Pump runs
1. Hose kinked.
but no water is
2. Pump is not primed.
discharged.
3. Defective impeller.
4. Suction lift too high.
5. Discharge height too great.
6. Clogged inlet.
Motor runs too
1. Voltage incorrect.
hot.
2. Restricted discharge hose.
3. Impeller damaged.
4. Plugged or kinked discharge.
5. Insufficient air flow on motor.
Flow rate is low. 1. Hose kinked.
2. Clogged impeller.
3. Worn impeller.
4. Excessive length of hose.
Pump will not
1. No power.
run.
2. Impeller jammed.
3. Motor overheated.
WARRANTY
This product is warranted for one year from the date of purchase.
forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves
defective due to defective materials or workmanship. This warranty does not cover replacement parts for
failure due to normal wear and tear. To obtain warranty service, contact the dealer from whom the product
was purchased. The manufacturer retains the sole right and option to determine whether to repair or replace
defective equipment, parts or components. Damage due to conditions beyond the control of the manufacturer
is not covered by this warranty.
THIS WARRANTY WILL NOT APPLY: (a) To defects or malfunctions resulting from failure to properly install,
operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from
abuse, accident or
negligence or use of inappropriate chemicals or additives in the water;
maintenance services and the parts used in connection with such service; (d) to units which are not installed
in accordance with normal applicable local codes, ordinances and good trade practices; and (e) if the unit is
used for purposes other than for what it was designed and manufactured.
RETURN OF WARRANTED COMPONENTS:
Possible Cause
9
Corrective Action
1. See priming instructions on page 6.
2. Move pump closer to water source.
3. Straighten hose.
4. Tighten fitting.
5. Repair or replace hose.
1. Straighten hose.
2. See priming instructions on page 6.
3. Replace impeller.
4. Move pump closer to water source.
5. Reduce discharge height.
6. Clean inlet.
1. Connect to 115 volt outlet.
2. Increase hose diameter to 3/4 in.
3. Replace impeller.
4. Clean and straighten hose.
5. Make sure ample fresh air is available
at the motor.
1. Straighten hose.
2. Clear obstruction.
3. Replace impeller.
4. Reduce length of inlet and outlet hose.
1. Verify that unit is plugged into 115 volt
outlet.
2. Clean pump cavity and impeller.
3. Motor has automatic thermal protector.
Wait fifteen minutes for motor to cool.