4. Insert the accessory tool in the keyless chuck and then turn the chuck firmly by hand until tight and
several clicks are heard.
5. Check that the accessory tool is held securely.
5.9 Drilling
1. Set the torque and operating mode selector ring to the
2. Set the forward/reverse switch to the "forward" position.
5.10 Screwdriving
1. Set the torque and operating mode selector ring to the required torque.
2. Set the forward/reverse switch to the desired direction of rotation.
5.11 Switching on
▶ Press the control switch.
Note
The running speed can be controlled smoothly right up to maximum speed by varying how far the
control switch is pressed in.
5.12 Switching off
▶ Release the control switch.
5.13 Removing the accessory tool
1. Set the forward/reverse switch to the middle position or remove the battery from the power tool.
2. Open the keyless chuck.
3. Pull the accessory tool out of the keyless chuck.
6 Care, maintenance, transport and storage
6.1 Care and maintenance of the power tool
WARNING
Electrical hazards. Improper repairs to electrical parts may lead to serious injuries.
▶ Electrical parts may be repaired only by trained electrical specialists.
▶ Keep the tool, especially its grip surfaces, clean and free from oil and grease. Do not use cleaning agents
containing silicone.
▶ Never operate the power tool when the air vents are blocked. Clean the air vents carefully using a dry
brush. Do not permit foreign objects to enter the interior of the tool.
▶ Clean the outside of the tool at regular intervals with a slightly damp cloth. Do not use a spray, steam
pressure cleaning equipment or running water for cleaning. This may negatively affect the electrical
safety of the power tool.
Note
To help ensure safe and reliable operation, use only genuine Hilti spare parts and consumables.
Spare parts, consumables and accessories approved by Hilti for use with the product can be
found at your local Hilti Center or online at: www.hilti.com
6.2 Care of the Li-ion battery
▶ Keep the battery clean and free from oil and grease.
▶ Clean the outer surfaces of the tool with a slightly damp cloth at regular intervals. Do not use cleaning
agents containing silicone.
▶ To achieve maximum battery lifetime, stop drawing power from the battery as soon as a significant drop
in the performance of the power tool is noticed.
▶ Charge the batteries using the Hilti chargers approved for use with Li-ion batteries.