3 - CONTROL PANEL DESCRIPTION

3
ON
2
1
11
ESP1-A
15
Input : 100-240V
6.3A 50/60Hz
AC
Output : 40/32/24 V
5.5 / 6.9 / 9.2A
DC
Class 2 power supply
Conforms to UL STD
1310, Certified to
CAN/CSA C22.2
STD NO. 223-M91
Desoutter Ltd
Outputs
Hemel-Hempstead
HP2 7BW UK
EPA
1 2 3 4 5 6 7
1
1 2 3 4 5 6 7
14
Legend
1
Connector to tool
2
Key setting lock
3
High / Low speed selection
4
Fonctions Led
5
OK Led
6
NOK Led
7
"Up selection" key
8
"Down selection" key
9
"Reset" key
10 "Select / Confirm" key
11 "Power / Clear" key
12 Voltage / Tool range selection switch
13 I/O connector
14 Configuration switch
15 Power switch
02/2017
ESP1-A
24V
32V
40V
Clear
Reset
10
Select tool
ON
OFF
SLB012/020
24/32V
Power
SLB030/050
32/40V
SN:
Date:
Inputs
Outputs
Do not input more
than 12VDC/10mA
2 3 4 5 6 7
8 9 10 11 12 13 14

4 - STARTING-UP

1. Before any connection check that the
controller is set properly according to the
4
tool that will be connected (see #12 on back
panel).
5
2. Connect the controller to the main supply and
connect the tool to the controller. Turn on the
6
power switch (15) on the back of the unit.
3. Check that the key lock setting (2) is set to
7
. If not change it.
4. Press the "Select" button (10) for 5 sec
9
until the display show "SL" then a flashing
number.
8
5. Press "Arrow up" button (7) or "Arrow down"
button (8) to change value.
6. Press "Select" button (10) to move to the
12
next parameters. Each time the name of the
parameter is displayed when the "Select"
button (10) is pressed.
7. When adjusting the value, press the "Power
/ Clear" button (11) to adjust decimals
(available for Lt and Ll).

5 - PROGRAMMING OPTIONS

13

5.1 - Program list (SL)

Set from 1 to 5.
If switch 6 is on then the controller will create a
sequence of the program in the ascendant order
(1 => 2 => 3 => 4 => 5).
If you need less than 5 programs in the sequence
then set the number of screw of the first unused
program to zero.
In this case it will stop that sequence and loop it
back to 1.

5.2 - Batch count (SC)

Batch count can be set from 1 to 99.
Depending on the position of switch 1 the
counting is increasing or decreasing.
The validation of the batch can be set to manual
or automatic with switch 3.
If set to manual the operator must press the
"Select" button (10) at the end of each batch to
validate it and start a new one.
Press the "Power / Clear" button (11) to reset the
counting if needed (disable if the key lock setting
is "On").

5.3 - Automatic signal reset (At)

Duration of both the output signal and sound for
the "OK ALL" event.
● From 0.0 to 9.9 sec.