To avoid electric shock, be sure the thermocouple has been
removed before changing to another measurement function.
5.6

Continuity Measurements

Measurements must not be realised in live circuits. Capaci-
tors must be discharged.
Do not realise measurements if the battery compartment is
open.
In order to realise continuity test it is necessary to realise the
following actions:
Insert the black test lead into the negative COM terminal and
the red test lead into the V· ·°C·°F·Hz positive terminal,
Set the function switch to the 
Use the MODE button to select continuity "
icons will change when the MODE button is pressed,
Touch the test probe tips across the circuit or component un-
der test,
If the resistance is < 40, a tone will sound.
5.7

Diode Measurements

In order to realise diode test it is necessary to realise the
following actions:
Insert the black test lead banana plug into the negative COM
jack and the red test lead banana plug into the V· ·°C·°F·Hz
positive jack,
36
WARNING:
WARNING:
WARNING:
CMP-1006 – USER MANUAL
position,
)
)
)
)"
. The display
)
)