Connect the unit to the flow-through filter.
Take the required distances into consideration. ( Distances to be adhered to)
Fit a slide valve in the water supply upstream of the inlet of the unit if the unit is to be installed below the water level.
This allows the water supply to be shut off for maintenance work.
ProfiClear Premium / ProfiClear Classic
This section describes the connection of the UVC clarifying unit Bitron with a pump fed system.
Please adhere to the instructions for use of the flow-through filter.
The bypass membrane is fitted on delivery and is located in the outlet opposite the inlet.
OASE recommends closing the bypass in the following situations:
– Acute problems such as disease or turbidity due to a build-up of bacteria.
– Low flow rates:
Bitron Eco 120 W: < 10000 l/h
Bitron Eco 180 W: < 13000 l/h
Bitron Eco 240 W: < 15000 l/h
How to proceed:
F, G
1. Insert the outlets with flat seals through the holes in the container wall.
2. Fitting the inlet:
– ProfiClear Premium: First screw the adapters onto the outlets and hand tighten. Then screw the 30° inlet bends
with the union nuts onto the adapters and hand tighten. Ensure that the openings point downward.
– ProfiClear Classic: Screw the inlet nozzles with the O rings onto the outlets and hand tighten.
3. Closing the bypass (optional):
– ProfiClear Premium: Screw the cover cap onto the outlet instead of the adapter and inlet bend.
– ProfiClear Classic: Screw the cover cap onto the outlet instead of the inlet nozzle.
4. Connect the Bitron to the filter pump. ( Connecting the inlet)
BioTec ScreenMatic
Please adhere to the instructions for use of the flow-through filter.
With bypass
The bypass membrane is fitted on delivery and is located in the outlet opposite the inlet.
How to proceed:
H
1. Insert the outlets with flat seals through the holes in the container wall into the distributor.
2. Screw the distributor nuts with O rings onto the outlets and hand tighten.
3. Connect the Bitron to the filter pump. ( Connecting the inlet)
Without bypass
OASE recommends closing the bypass in the following situations:
– Acute problems such as disease or turbidity due to a build-up of bacteria.
– Low flow rates:
Bitron Eco 120 W: < 10000 l/h
Bitron Eco 180 W: < 13000 l/h
Bitron Eco 240 W: < 15000 l/h
How to proceed:
I
1. Turn the bypass holder counterclockwise until it makes an audible click and remove it from the outlet.
2. Pull the bypass membrane out of the bypass holder and fit the bypass closure onto the bypass holder.
– The bypass closure can only be fitted onto the bypass holder in one position.
3. Insert the bypass holder into the outlet and turn it clockwise until it makes an audible click.
– The bypass holder is locked in place.
4. Insert the outlets with flat seals through the holes in the container wall into the distributor.
5. Screw the distributor nuts onto the outlets and hand tighten.
6. Connect the Bitron to the filter pump. ( Connecting the inlet)