4
5
Additional functions
6
Devices with special features
7
Fault diagnosis
8
Table : Fault diagnosis
4
Image: G
Test input: The WS/WE14-2 sensor features a test input ("TI" or "Test" on the connec‐
tion diagram [B]), which can be used to switch the sender off and therefore check that
the sensor is functioning correctly: If female cable connectors with LED indicators are
used, you must ensure that the TI is assigned accordingly.
There must be no object between the sender and receiver; activate the test input (see
the connection diagram [B], TI at 0 V). The send LED is shut down or the detection of an
object is simulated. Refer to Graphics C and G to check the function. If the switching
output fails to behave in accordance with Graphic C, check application conditions. See
section Fault diagnosis.
WS/WE14-2P410S01: infrared light, sensing range max. 0–20 m
Table Fault diagnosis indicates which measures are to be taken if the sensor stops working.
LED indicator/fault pattern /
LED indicator/fault pattern
Green LED does not light up /
Green LED does not light up
Green LED does not light up /
Green LED does not light up
Cause /
Cause
No voltage or voltage below
the limit values /
No voltage or voltage below
the limit values
Voltage interruptions /
Voltage interruptions
Measures /
Measures
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons) /
Check the power supply,
check all electrical connecti‐
ons (cables and plug connecti‐
ons)
Ensure there is a stable power
supply without interruptions /
Ensure there is a stable power
supply without interruptions