ADDITIONAL FUNCTIONS

en
6
Additional functions
24
O P E R A T I N G I N S T R U C T I O N S | WSE26
Table 13: Push-pull, PNP, NPN
PNP
Push-pull
NPN
PNP
Push-pull
NPN
Alarm
Alarm output: The sensor (WSE26) features a pre-failure notification output ("Alarm"
in the connection diagram
[see table
only ready for operation to a limited extent. The LED flashes in this case. Possible
causes: sensor is contaminated, sensor is out of alignment. In the good state: LOW (0),
if excessively contaminated HIGH (1).
Health
Health output: The sensor (WSE26) features a pre-failure notification output ("Health"
in the connection diagram
[see table
only ready for operation to a limited extent or the cable has been interrupted. Possible
causes: Sensor is contaminated, sensor is out of alignment, cable is damaged. In the
good state: HIGH (1), if excessively contaminated or in the event of cable interruption
LOW (0). The yellow LED indicator flashes in this case.
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
3]), which issues a notification if the sensor is
3]), which issues a notification if the sensor is
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
8020358.1DS8/2021-11-24 | SICK
Subject to change without notice