7
COMMISSIONING
7.3
Setting
7.4
Additional functions
10
Operating reserve
1000
100
10
1
m
4
(feet)
(13.12)
Use and
see table 3, page 8
to behave in accordance with the table, check the application conditions,
bleshooting table", page
11.
Figure 4: Sensing range
Table 5: Definition of sensing range
1
Sensing range
1
Sensitivity setting
Sensor which it is not possible to set: The sensor is adjusted and ready for operation.
The sensitivity is adjusted with the potentiometer (type: 270°). Clockwise rotation:
operating reserve increased; counterclockwise rotation: operating reserve reduced. We
recommend setting the potentiometer to "Maximum".
The sensor is adjusted and ready for operation.
Alarm
Test input
Test input
8
12
(26.25)
(39.37)
(52.49)
Distance in m (feet)
to check the function. If the switching output fails
1
GRSE18(S)V
0 ... 15 m
16
see „Trou‐
8021182.1ABM / 2020-12-21 | SICK
Subject to change without notice