Alarm
Alarm output: The sensor (WLA16) features a pre-failure notification output ("Alarm" in
connection diagram
[see table
for operation to a limited extent. The LED flashes in this case. Possible causes: Sensor
is contaminated, sensor is out of alignment. In the good state: LOW (0), if excessively
contaminated HIGH (1).
Health output: The sensor (WLA16) features a pre-failure notification output ("Health"
in connection diagram
[see table
ready for operation to a limited extent or the cable has been interrupted. Possible
causes: Sensor or reflector is contaminated, sensor is out of alignment, cable is dam‐
aged. In the good state: HIGH (1), if excessively contaminated or in the event of cable
interruption LOW (0). The yellow LED indicator flashes in this case.
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
+ (L+)
Q ≤ 100 mA
Push-pull
‒ (M)
2]), which issues a notification if the sensor is only ready
2]), which issues a notification if the sensor is only
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)
+ (L+)
PNP
Q ≤ 100 mA
NPN
‒ (M)