Set; Setting Smartdoor ™ 'S Sensitivity Level; Understanding Sensitivity And The Active Area; Programming A New Smartkey - Petsafe IRIS Electronic SmartDoor Guía Para El Uso

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NOTE:
The SmartDoor
is designed with an electric motor to release and unlock flap when a
SmartKey
is detected. Do not allow your pet to run or charge through the SmartDoor
variable radio-frequency interferences it could take several seconds for SmartKey
to read properly and SmartDoor
's flap to unlock.

SET

A. Setting SmartDoor
's Sensitivity Level
It is necessary to set your SmartDoor
's sensitivity level so your pet's SmartKey
due to location or application material, such as radio-frequency interferences, wood or metal
door installations.
To begin, it is recommended to use the split ring (included) to attach the SmartKey
on your pet's collar. Also do not use metal tags as the additional metal can cause radio-frequency
interference and hinder the detection of your pet's SmartKey
"product in use" steps:
1. Put the dog's collar on your leg just below your knee. Tape
may be used to secure the collar, if necessary. See A.
2. Stand directly in front of the SmartDoor
is approximately 2.5 feet (76 cm) from the SmartDoor
3. Put the SmartDoor
in the UNLOCKED Mode. (See page 6
for operational instructions).
4. Put the SmartDoor
in the Sensitivity Test Mode by
holding down the MODE-RESET and LEARN buttons at the
same time until all three lights flash once.
5. Turn the Sensitivity Knob counter clockwise to the
minimum position, then turn the Sensitivity Knob
clockwise until all lights begin to flash again.
6. Slowly continue to adjust the Sensitivity Knob clockwise
until you see a minimum of six consecutive flashes and
stop adjusting. Do not adjust higher than necessary.
7. Put the SmartDoor
in AUTOMATIC Mode and step away
at least 10 feet (3 m), allowing the door to automatically
lock. This may take up to fifteen seconds after the
SmartKey
no longer is detected.
8. Now confirm the sensitivity level by approaching the
SmartDoor
again. The door should unlock when you
step within approximately 2 feet (60 cm) in front of the
SmartDoor
.
B. Understanding Sensitivity and the
Active Area
The Active Area is the area where the SmartDoor
consistently open based on your adjustment of the
sensitivity level. In the Fringe Area the SmartDoor
open inconsistently due to variables of radio-frequency
interferences or reflections. In the Inactive Area the door
will generally not unlock automatically. See B.
You may see slight differences between Outside and Inside
Active Areas due to radio-frequency interferences.
Depending on location
and application
~ 2.5 feet (76 cm)
~ 6 feet (183 cm)
10
1-800-732-2677
works properly
. Now, continue with the following
A.
so the SmartKey
.
B.
Door - Top View
Outside
Inactive
will
may
Fringe
Active
Active
Fringe
Inside
Inactive
C. Programming a New SmartKey
. Due to
To reduce error while programming, remove the RFA-67 battery from all programmed SmartKeys
's unique code
except the one you are programming. Press and hold the LEARN button until the green light
illuminates and begins to flash, now release the button. Bring the SmartKey
green light and the light will stop flashing and illuminate for two seconds. Now your new SmartKey
has been programmed and added to memory. Up to five different SmartKeys
a time.
D. Attach the SmartKey
A split key ring has been provided to attach to your pet's
collar and should hang under the pet's neck.
to the D-ring
The SmartDoor
pre-programmed and ready to use.

OPERATE

Operating Your SmartDoor

LOCKED MODE – Does not allow entry or exit for any pet. The SmartDoor
in LOCKED MODE and when batteries are placed in the SmartDoor
set: hold the MODE-RESET button until the red light illuminates and release when selected.
UNLOCKED MODE – Allows entry and exit for all pets. To set: hold the MODE-RESET button until
the green light illuminates and release when selected.
AUTOMATIC MODE – Allows entry and exit for a pet wearing a programmed SmartKey
to five SmartKeys
automatic mode. To set: hold the MODE-RESET button until the yellow light illuminates and
release when selected.
NOTE:
If at any time the red light remains illuminated, replace with a set of fresh batteries. If that
does not reset the red light, please call our Customer Care Center for additional help.
Illuminating Color
RED
GREEN
YELLOW
RED, GREEN AND YELLOW
SmartDoor
not respond to the
presence of the
SmartKey
when my
pet is directly in front
of the SmartDoor
within three seconds
to the Pet's Collar
includes (one) SmartKey
which comes
can be programmed into one SmartDoor
Condition
Solid only for two seconds after
selecting LOCKED Mode
Flashing
Constant solid
Solid only for two seconds after
selecting UNLOCKED Mode
Flashing
Solid only for two seconds after
selecting AUTOMATIC Mode
Flashing
Flashing at the same time
Troubleshooting
does
• Check that the SmartDoor
• Check that the SmartKey
• Check sensitivity level has been properly set, see page 10.
• Check that the RFA-67 battery in the SmartKey
• Check that the batteries in the SmartDoor
• If the condition persists, check that there are no radio-frequency
transmitting devices or electronic devices that radiate electrical
energy, which may interfere with the operation of the SmartDoor
www.petsafe.net
directly below the
can be added, one at
ships from the factory
, it will enter LOCKED MODE. To
; up
for selective entry and exit during
Pet Door Status
LOCKED Mode
Low battery alert
Internal failure has occurred
UNLOCKED Mode
Learn Mode
AUTOMATIC Mode
Error alert
Sensitivity Test Mode
is in AUTOMATIC Mode.
has been programmed to the SmartDoor
is screwed in tightly.
are fresh.
.
.
11

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Ppa11-10709

Tabla de contenido