Malfunction
Motor runs very
slowly.
Motor unit
becomes hot.
Running time of
a fully charged
battery is too short
and / or blades are
getting hot.
Lowest LED on
charger is not lit.
Normal charging
does not start when
the discharged
battery is inserted.
Bottom LED lights
up green.
Top LED lights
up red.
Translation of the original instructions / Cattle and Horse Clipper
Cause
Clipper blades were not
oiled sufficiently.
Clipping pressure
too strong.
Battery almost
discharged.
Motor and/or electronics
defective.
Clipping pressure
too strong.
Motor faulty.
Clipper blades were not
oiled sufficiently
Flat, not fully charged
or faulty battery is
being used.
Charging station is not
connected to the power
supply.
Electronics or power
supply unit defective.
Battery terminals and/or
charger are dirty.
Faulty battery.
Electronics are defective. Notify customer service.
Battery is deeply
discharged, the charger
is trying to boost the
battery voltage.
Faulty battery.
Rectification
Lubricate the clipping blades.
Reduce the clipping pressure,
as described in chapter 6.5.
Charge battery.
Notify customer service.
Reduce the clipping pressure,
as described in chapter 6.5.
Notify customer service.
Oil clipper blades.
Only use intact, fully charged
original batteries.
Connect the charging station
to the power supply.
Notify customer service.
Clean contacts.
Replace battery.
If it is successful, normal
charging starts. (Never store
batteries in the discharged state).
If it is not successful, the lowest
LED lights up red (see the
following table).
Replace battery.