Additional charge
The refrigerant is pre-charged in the outdoor unit. If the
piping length is less than 7.62m (25ft), then additional charge
after vacuuming is not necessary. If the piping length is more
than 7.62m (25ft), then use the additional charge valve as
indicated in the table.
Charge operation
This operation must be done by using a gas cylinder and a
precise weighing machine. The additional charge is topped-
up into the outdoor unit using the suction valve via the ser-
vice port.
•
Remove the service port cap.
•
Connect the low pressure side of the charging gauge to
the suction service port center of the cylinder tank and
close the high pressure side of the gauge. Purge the air
from the service hose.
•
Start the air conditioner unit.
•
Open the gas cylinder and low pressure charging valve.
•
When the required refrigerant quantity is pumped into
the unit, close the low pressure side and the gas cylinder
valve.
•
Disconnect the service hose from service port. Put back
the service port cap.
IR signal receiver
When an infrared remote control operating signal has
been transmitted, the signal receiver on the indoor unit
will make a <beep> sound to confirm acceptance of the
signal transmission.
Cooling unit
The table shows the LED indicator lights for the air condi-
tioner unit under normal operation and fault conditions.
The LED indicator lights are located at the bottom right
side of the air conditioner unit.
LED Indicator Lights : Normal Operation And Fault Conditions For Cooling Unit
Continuously
once every 2 sec.
twice every 2 sec.
3 times every 2 sec.
ON
Additional charge in gram (For R22/R407C models)
Model
07F / 10F/ 15F
07FR / 10FR / 15FR
Additional charge in gram (For R410A models)
Model
07F / 10F/ 15F
07FR / 10FR / 15FR
Indoor Unit
INDICATOR LIGHTS
LED Indicator Lights for Cooling Unit
Operation / Fault Indication
Timer on.
Sleep mode on.
Dry mode.
Frost prevention.
Room air sensor contact loose/short.
Indoor coil sensor contact loose/short.
Sensor contact problem, compressor
overload protection trip or gas leak
ON or OFF
1-8
10m/32.8ft
35
20F
35
25F
90
50
20FR
60
25FR
120
10m/32.8ft
35
20F
35
25F
80
45
20FR
55
25FR
110
Liquid side
Discharge
Valvet
Gas side
Suction
Check
Valve
Valve
Hi
Low
Close
IR Receiver
LED indicator lights
Timer
Sleep mode
Clean the filter and switch to high fan.
Call your dealer.
Call your dealer.
Call your dealer.
12m/39.4ft 15m/49.2ft
65
–
65
110
165
280
90
–
110
185
220
370
12m/39.4ft 15m/49.2ft
60
–
60
100
150
255
80
–
100
165
200
335
Outdoor Unit
Open
Open
Power ON
Dry mode
Action
–
–
–
Blinking