Auto-Off Timer - Mitsubishi Electric Lossnay PZ-61DR-E Manual De Instrucciones

Ocultar thumbs Ver también para Lossnay PZ-61DR-E:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 115
Controller operation-Function settings
Timer

Auto-Off timer

Button operation
1
On/Off timer
On
Repeat
Auto-Off
Stop in
Setting display:
Cursor
F1
2
Auto-Off
Stop in
Select:
Cursor
F1
3
Auto-Off
Stop in
Select:
Cursor
F1
20
Timer
Yes
Off
Yes
No
--- min
F2
F3
F4
Auto-Off timer
No
Yes
min
Cursor
F2
F3
F4
Auto-Off timer
No
Yes
min
Time
F2
F3
F4
Bring up the Timer setting screen.
(Refer to page 18.)
Select "Auto-Off", and press the SELECT
button.
The Auto-Off timer will not work in the following cases:
when Auto-Off timer is disabled, during an error,
during check (in the service menu), during
remote controller diagnosis, when the clock is not
set, during Function setting, when the system is
centrally controlled (when On/Off operation from
local controller is prohibited).
The current settings will appear.
Move the cursor to the "Auto-Off" or "Stop in ---
min" with the F1 or F2 button.
Change the setting with the F3 or F4 button.
Stop in --- min: Timer setting (The settable
range is 30 to 240 minutes in
10-minute increments.)
Main
P
Tabla de contenido

Solución de problemas

loading

Tabla de contenido