Renishaw ACR2 Guia De Instalacion página 29

Tabla de contenido
Manual No. H-1000-4045
Ensure port is in its lower position
Upper location pin
Figure 10 – ACR2 port datuming procedure
Only one port is shown for clarity.
4.
Take four points around the full diameter of the upper location pin in
the ZX plane (assuming the rack is oriented to the CMM axes as
shown on this page).
5.
Use the four points to create a circle.
6.
Use the centre point of the circle as the coordinates for the pin datum
in the X and Z axes, X
7.
Take one point on the end of the upper location pin in the Y axis and
use it as the coordinate for the pin datum in the Y axis, Y
AUTOMATIC OPERATION
NOTE
and Z
.
P
P
.
P
29