DESCRIPTION OF ADVANCED PARAMETERS
The advanced parameters cannot be accessed by the final user as they are all inside a hidden menu.
These parameters can be changed to optimise operation of the inverter, to solve problems related to special installations, , to carry out
pressure and flow sensor calibration or to check the operating log.
To access the advanced parameters menu, simply press and hold the central key for approximately 5 seconds while on the temperature
display page. The system requires entry of a value from 0.0 to 5.9 in order to directly view one of the parameters of the menu.
Parameters from 0.0 to 1.1 correspond to the basic parameters accessible by the installer, while parameters from 1.2 to 5.9 are advanced
parameters as indicated in the table below.
Ti= 35° C
Ta= 35° C
Press for 5 seconds
Sel .par
Select the parameter number
0.0
Confirm using the central key to access the required parameter.
REF.
PARAMETER
1.2
Minimum frequency
1.3
Stop frequency
1.4
Nominal motor frequency
1.5
Switching frequency
1.6
Frequency correction
1.7
Soft-start
2.0
Flow switch activation
2.1
Command source
2.2
Auxiliary contact function
2.3
I/O board input function
2.4
I/O board output function
2.5
Delay on stop
2.6
Autoreset interval
2.7
No. autoreset tests
2.8
Total automatic reset
3.0
Pressure calibration 0.0 Bar
3.1
Pressure calibration 5.0 Bar
3.2
Flow sensor calibration
3.3
Pressure test
3.4
Flow switch test
3.5
Software Release
3.6
Power supply timing
3.7
Pump timing
3.8
Last error
3.9
Start-up
4.0
Vboost
4.1
Dry run
4.2
Protection starts per hour
4.3
Anti-blockage protection
4.4
Dead time PWM
4.5
Ki
4.6
Kp
4.7
Boost time
5.0
Ta max
5.1
Tm max
5.2
Ta reduction index
5.3
Tm reduction index
–
from 0.0 to 1.1 basic parameters
DESCRIPTION
Minimum motor start-up frequency
Motor shutdown frequency
Maximum nominal motor frequency
PWM Switching frequency
Maximum frequency correction
Soft-start activation/deactivation
Flow switch activation or deactivation
Source of manual or automatic command
Selection of auxiliary contact function
Function of I/O auxiliary board input contact
Function of I/O auxiliary board output contact
Delay on shutdown after closure of utilities
Time interval between autoreset attempts
Number of autoreset attempts
Enabling of overall reset of all alarms
Calibrates the pressure sensor at 0 Bar
Calibrates the pressure sensor at 5 Bar
Calibrates the flow sensor
Current pressure test signal
Flow switch test signal
Software Release
Inverter power supply timer
Electric pump operation timer
Log of last error
Pump start-up counter
Voltage boost at 0Hz
Time delay before activation of the dry run protection
Activation or deactivation of the control on the number of start-ups per hour (leak checks)
Activation or deactivation of a function that automatically starts up the pump after 24
hours of disuse
Dead time PWM setting
PID controller integral constant
PID controller proportional constant
Boost time at maximum frequency with soft start disabled
Maximum ambient temperature
IGBT module maximum temperature
Frequency reduction index on ambient temperature
Frequency reduction index on module temperature
22
IT
–
from 1.2 to 5.9 advanced parameters.
EN
PT
RU
DE
ES
FR
RO