DESCRIPTION
Sirio Entry is an electronic device, employing inverter-based technology, which controls motor pump
stopping and starting functions.
Thanks to the particular type of techn o l o g y u s e d , i t c a n m o d u l a t e t h e f r e q u e n c y ( H z ) o f t h e m o t o r ' s i n p u t
current to alter the speed (rpm) according to the water delivery rate required from the system.
This way, the value of the pressure reaching the user appliances is maintained constant all the time and
the motor' s absorption is always proportional to the actual system requirements, resulting in notable
energy savings over time.
SPECIFICATIONS
P o w e r m a i n s s u p p l y : ......................... .single-phase, 230Vac ±10% - 50/60Hz
Mo t o r p o w e r s u p p l y : ...........................single-phase 230V~
Ma x i m u m p o w e r a b s o r p t i o n : ..................1 5 0 0 W – 2Hp
Ma x i m u m m o t o r p h a s e c u r r e n t : ...............9 . 7 A r m s
Ma x . l i n e a b s o r p t i o n : ...................... ......1 2 A @ 2 3 0 V ~
Ma x . a l l o w a b l e p r e s s u r e : ................ .... . . . . . 8 0 0 K P a ( 8 b a r )
Ma x . l i q u i d t e m p e r a t u r e : ................... . . . . 50°C
Max. theoreti c a l f l o w r a t e : .....................1 5 0 l / m i n – 9m
/h – 9000 l/h
3
Set-p o i n t a d j u s t m e n t r a n g e : ................... . 1 . 5 ÷ 7 b a r
S t a r t p r e s s u r e a d j u s t m e n t r a n g e : ...............1 ÷ 6 . 7 b a r
H y d r a u l i c c o n n e c t i o n ...........................1 " ¼ m a l e -male
F r e q u e n c y m o d u l a t i o n r a n g e : ................ ...2 5 ÷ 5 0 H z ( 3 0 -60Hz optional)
Deg r e e o f p r o t e c t i o n : ..................... .... . I P X 5
We i g h t .............................................1 . 6 K g
D i m e n s i o n s ........................................ 2 5 4 x 1 4 7 x 1 4 3 m m
T y p e o f a c t i o n . . . .................................. 1 ( a c c o r d i n g t o E N 6 0 7 3 0 -1)
FEATURES
Constant pressure due to motor pump speed regulation
Energy savings due to less pump absorption
Gradual pump start and stop reduces hammering
Protection against dry running in the event of water shortage during intake
Automatic reset in the event of dry running, with autonomous error condition recovery
Efficient leakage monitoring to protect pump in the event of repeated restarts
Digital pressure display
Operation/error status signalling via LEDs and on-screen alerts
Auxiliary contact for remote control, pair connection or double set-point
Soft-start can be enabled to allow a gradual start of the motor pump
Extractable terminals to facilitate wiring
Possibility of interfacing two devices as part of the pressurisation units
23