Water Hammer Arrester
3/4"-1/2" Reducing Adapter
Plug all unused
outlets.
1/2" Union
1/2" Tubing
1/2" Tubing
To Handshower
3. Create Piping Assembly
Using copper elbows, tees, and tubing, join the three 1/2" unions into a single 3/4" outlet (as
illustrated above).
Verify fit, making adjustments as needed.
Solder all piping assembly connections.
Solder the piping assembly to the 1/2" unions.
Install a water hammer arrestor (Sioux Chief model #652AD or equivalent) as close to the piping
assembly as possible.
Route piping from outlet 1 to the handshower installation location.
Install brass plugs to all unused outlets.
Refer to the Installation Guides for all other components to complete system installation.
Turn on the water and power to the system.
Run water into the bath and check all connections for leaks.
Kohler Co.
1/2" Tubing
1/2" Elbow
1/2" Tubing
1/2" Tee
1/2" Tubing
1/2" Tee
1/2" Tubing
1/2" Elbow
1/2" NPT Female Adapter
1/2" Tubing
3/4"-1/2" Reducing Tee
3/4" Tubing
3/4" Union
3/4" Tubing
5
To Spout
3/4" Tubing
1093628-2-B