English
Connecting to Power Supply
The voltage and frequency of the
machine (see rating plate) must match
the voltage and frequency of the power
connection.
The minimum fuse protection of the
power connection must comply with the
specifications – see "Specifications".
The machine must be connected to the
power supply via an earth-leakage
circuit breaker to disconnect the power
supply if the differential current to earth
exceeds 30 mA.
The power connection must correspond
to IEC 60364 and relevant national
regulations.
Depending on the supply voltage and
cord length, the minimum conductor
cross section of the extension cord must
be as follows:
Cord length
Minimum cross
section
220 V – 240 V:
up to 20 m
1.5 mm
20 m to 50 m
2.5 mm
100 V – 127 V:
up to 10 m
AWG 14 / 2.0 mm
10 m to 30 m
AWG 12 / 3.5 mm
40
Plug the power cord (1) into the
N
coupling (2) of the extension cord
2
2
2
2
1
2
Strain relief
3
5
4
Make a loop in the extension
N
cord (3)
Guide the loop (3) through the
N
opening (4)
Guide the loop (3) over the hook (5)
N
and pull it tight
Plug the extension cord into a
N
properly installed outlet
FSE 60, FSE 71, FSE 81