Commissioning slaves
IPE 2700 - 5000 SN 05
7. CAN network list is set up.
If the search is set to manual, the IDs must be confirmed at each slave before
commissioning of the master is continued.
Confirm with
.
NOTE
Depending on the side of the network, it may take a moment until the master has
found all slaves and added them to the list.
8. Set password centrally for all connected units. Select Password with
The default password is:
******** (= 8 asterisks)
A new password can be set with
Confirm the password with
NOTE
Please note:
Only digits between 0 – 9 and letters between a – z and A – Z are permitted.
The password always has 8 characters. If the password you entered has less than
8 characters, the remaining characters will be filled with "*".
Example:
The password you have chosen is "Solar". This password has 5 characters. The sys-
tem automatically adds three "*", so that the password becomes "Solar***".
9. Completion of commissioning
Confirm overview with
After a master has been defined, the display for requesting the CAN-ID is automati-
cally shown on the display on each slave in a manual device search.
1. Request CAN ID (this step is only necessary for manual device searches)
Request the next higher free ID from the master with
ID with
.
The master assigns a free ID to the slave. Confirm the ID within 5 seconds with
.
Request further IDs with
Confirm the CAN ID with
/
/
/
.
.
/
.
within 5 seconds.
Commissioning
.
as an option.
or the next lower free
43