5WMWS-GR
Air Intake
Grille
WATER SOURCE HEAT PUMP UNIT
The indoor unit must be installed in such a way so as to
prevent short circuit of the cool discharged air with the hot
return air. Please follow the installation clearance shown in
the figure. Do not place the indoor unit where there could be
direct sunlight shining on it. Also, this location must be
suitable for piping and drainage, and be away from doors or
windows.
50.0 mm
Air Flow
Direction
Maintenance &
Servicing Space
Routing Of Piping
Remove the screw holding the front panel.
Piping Routing
2
1
INSTALLATION DIAGRAM
Air Filter
Indicator
Drain Hose
Lights
Signal Receiver
INSTALLATION OF THE INDOOR UNIT
50.0 mm
3
4
5
1-3
Front Frame
Back Housing
ON/OFF Switch
Return Water
Supply Water
Liquid Pipe
Gas Pipe
The refrigerant piping can be routed to the unit in a
number of ways (left or right from the back of the unit), by
using the cut-out holes on the casing of the unit (see figure).
Bend the pipes carefully to the required position in order to
align it with the holes. For the right hand and rear side out,
hold the bottom of the piping and then position it to the
required direction (see figure). The condensation drain hose
can be taped to the pipes.
Right & Rear Side Routing
Drain hose
Fix with vinyl tape
Refrigerant Piping
Unit piping