Indoor Unit

Air Intake Grille
Air Discharge
Louvre
Air Discharge
Grille
Air Intake
Air Discharge
Nozzle
The outdoor unit must be installed in such a way, so as to
prevent short circuit of the hot discharged air or obstruction
to the smooth air flow. Please follow the installation clear-
ance shown in the figure. Select the coolest possible place
where intake air temperature is not greater than the outside
air temperature (maximum 45°C/113°F).
Installation clearance
Dimension
A
Minimum
Distance, mm
300
(in)
(11.8)
Note: If there is any obstacle higher than 2m, or if there is
any obstruction at the upper part of the unit, please allow
more space than the figure indicated in the above table.

INSTALLATION DIAGRAM

Indicator Lights
Signal Receiver
Air Intake

INSTALLATION OF THE OUTDOOR UNIT

B
C
D
500
1000
300
(39.4)
(11.8)
(19.7)
Air Filters
A
C
1-3
Front Frame
Back Housing
On/Off Switch
Drain Hose
Refrigerant Piping
Outdoor Unit
B
D