Reversed Inlet Supplies (cont.)
NOTE: The temperature adapter can only be removed when the
retaining tabs are oriented horizontally.
Use a screwdriver to flex the retaining tabs on the temperature
adapter outward. Remove the temperature adapter.
Slowly loosen the head nut, turning it counterclockwise. This will
begin to draw the cartridge out of the valve body.
NOTE: Some water may be released. Use a bucket and towels to
contain the water.
Pull the head nut with the cartridge out of the valve body.
NOTE: Two seals may fall out when the cartridge is removed. Set
the seals aside.
Rotate the cartridge 180°.
Verify the cold cartridge inlet is on the left when the valve stem
adapter is facing you.
NOTE: The hot and cold cartridge inlets are identified on the top
and sides of the cartridge tabs. The tabs are labeled "H" and "C" to
identify hot and cold.
Reinstall the seals onto each side of the cartridge.
Carefully push the cartridge back into the valve body. Make sure
both cartridge tabs are properly seated inside the cartridge slots
of the valve body.
Tighten the cartridge into the valve body. Do not overtighten.
Return the integral supply stops back to their original position.
Align the temperature adapter with the temperature drive tab in
the 12 o'clock position.
Flex the retaining tabs on the temperature adapter outward with
a screwdriver and reinstall it. It can only be installed in one
position with the retaining tabs aligned horizontally.
Kohler Co.
13
1066046-2-B