Comunello QUAD 24V 2M ONE Instrucciones De Uso página 31

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

SETTING THE OPERATION (MODE) OF THE ACCESSORIES).
24V+
+ Output for indicator light 24VDC (20mA max)
24V-
- Output for indicator light 24VDC
NO:
Voltage free NO contact output 24VDC 1A max
C:
Voltage free contact output (common)
Flashing light output
= moving gate
Output enabled (ON) = open gate
Output disabled (OFF) = closed gate
AUX UTILITY OUTPUT (OUT AUX) ELECTRIC LOCK - FLASHING
LIGHT
The control unit has a dedicated output for piloting, alternatively, electric
locks of the 24V
12W impulse type or flashing lights of the 24V
5W continuous type. If the output is programmed as an ELECTRIC stop
command, the command is enabled at each initial opening movement for
1
2
3
4
5
6
about 3 sec. If the output is programmed as AUX FLASHING LIGHT, it will
be piloted by the control unit as a standard flashing light.
Output terminals for connection of the auxiliary utility programmable
alternatively as:
ELECTRIC stop command
AUXILIARY FLASHING LIGHT
NOTE: 24V
5W max. load (continuous), 12W max. (impulse)
1
2
3
4
5
6
7
8
9
O
N
DIP-SWITCH 7 ON = Auxiliary Flashing Light
DIP-SWITCH 7 OFF = Electric lock command
BUFFER BATTERY
The control unit allows connection of a buffer battery kit (code AC51) which
allows the barrier to perform several complete open/close manoeuvres at
slow speed.
Input for connection of buffer battery kit.
1
2
3
4
5
NOTE: Use only ONE buffer battery kits (code AC51)
7
8
9
10
10
1
2
3
4
5
6
7
8
9
10
OPERATOR CONTROL
OPERATION OF 1 or 2 OPERATORS:
The control unit allows you to select operation with either 1 or 2 operators:
1
2
3
4
5
6
O
N
DIP-SWITCH 5 ON = Operation with 1 Operator
DIP-SWITCH 5 OFF = Operation with 2 Operators
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
NOTE: Operation with 1 Operator (single operator) requires connection of
the single operator to terminal MOT 1.
CHANGING ROTATION DIRECTION AND START PRIORITY
The control unit features three slide-switches that allow you to set or
change the direction of rotation of the operators (Operator 1 and Operator
2) and if necessary, invert the sequence (priority) in which Operator and
Operator start.
NOTE: Operator 1 is the operator that starts first in the automation with two
operators (e.g. dual swing gate).
A set of (slide) selector switches allow you to control rotation of the operators.
INV1
Invert Operator 1 Rotation
INV2
Invert Operator 2 Rotation
INV1-2
Invert Operator 1 with Operator 2 (opening priority)
NOTE: A variation of the slide-switches requires pressing the RESET button
on the control unit to enable the new setting.
CONDOMINIUM OPERATION
In the condominium operating mode, during opening and pause, the control
unit does not respond to commands coming from accessories connected
to the BUS line with open-close function (AUTO-PP) and from the remote
controls. During the closing phase, instead, this operating mode inverts the
movement.
O
1
2
3
4
5
6
N
DIP-SWITCH 2 ON = Condominium Operation Enabled
DIP-SWITCH 2 OFF = Condominium Operation Disabled
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
LEAF OFFSET (DELAY - OPERATOR DELAY)
If you use the configuration for automation with 2 operators, you may need to
enter a leaf delay time (delay of movement between Operator 1 and Operator
2).
1
2
3
4
5
6
O
N
DIP-SWITCH 6 ON = Leaf Delay Enabled (fixed 4" during opening and
closing movement)
DIP-SWITCH 6 OFF = Leaf Delay Disabled (fixed 4" only during closing
movement)
6
7
8
9
10
NOTE: The leaf delay, if set, is enabled both during opening and closing.
NOTE: A variation of the dip-switches requires pressing the RESET
button on the control unit to enable the new setting.
RELEASE STROKE
This function sends a closing command for approx. 1 second at the start of
an opening cycle: this facilitates release of the lock to allow correct execution
of the opening cycle.
COMUNELLO ®Copyright 2015 - All right reserved
7
8
9
10
7
8
9
10
7
8
9
10
31
Tabla de contenido
loading

Tabla de contenido