The ID assignment logic is as follows:
DIP1 = OFF
ON
DIP2 = OFF
1
2
3
DIP3 = OFF
DIP1 DIP2 DIP3
DIP1 = ON
ON
DIP2 = OFF
1
2
3
DIP3 = OFF
DIP1 DIP2 DIP3
DIP1 = OFF
ON
DIP2 = ON
1
2
3
DIP3 = OFF
DIP1 DIP2 DIP3
DIP1 = ON
ON
DIP2 = ON
1
2
3
DIP3 = OFF
DIP1 DIP2 DIP3
DIP1 = OFF
ON
DIP2 = OFF
1
2
3
DIP3 = ON
DIP1 DIP2 DIP3
DIP1 = ON
ON
DIP2 = OFF
1
2
3
DIP3 = ON
DIP1 DIP2 DIP3
DIP1 = OFF
ON
DIP2 = ON
1
2
3
DIP3 = ON
DIP1 DIP2 DIP3
DIP1 = ON
ON
DIP2 = ON
1
2
3
DIP3 = ON
DIP1 DIP2 DIP3
SETTING THE OPERATION (MODE) OF THE ACCESSORIES
All accessories can be set to its type of OPERATION (e.g.: photocell
enabled on closing, I/O board with INDICATOR LIGHT output, etc.); this
type of configuration can be done directly on the board by setting the
corresponding DIP-SWITCH:
Dip switch MODE
DART
INTERFACE I/O
Dip switch MODE
28
COMUNELLO ®Copyright 2015 - All right reserved
ID = Accessory no. 1
ID = Accessory no. 2
ID = Accessory no. 3
ID = Accessory no. 4
ID = Accessory no. 5
ID = Accessory no. 6
ID = Accessory no. 7
ID = Accessory no. 8
Dip switch MODE
INDEX
DIP1 = OFF
ON
DIP2 = OFF
1
2
DIP1
DIP2
DIP1 = ON
ON
1
2
DIP2 = OFF
DIP1
DIP2
DIP1 = OFF
ON
1
2
DIP2 = ON
DIP1
DIP2
ON
DIP1 = ON
1
2
DIP2 = ON
DIP1
DIP2
The operating mode depends on the particular accessory.
TABLE OF OPERATION (MODE) OF THE ACCESSORIES
OPER.
TYPE 1
PHOTOCELL RX
ON CLOSE
KEY SWITCH
[AUTO-PP]
[PED]
INTERFACE I/O
In =
[AUTO-PP]
[PED]
Out = AUX
FLASHING LIGHT
Defined by
Control unit
ATTENTION, PLEASE! For use and setup made by the Comunello
One App please set all MODE dip-switches into OFF position.
PHOTOCELL
RX PHOTOCELL TYPE 1 "ON CLOSE":
If the photocell is engaged during closing, it runs a full inversion (opening)
cycle. The photocell is not activated during opening.
RX PHOTOCELL TYPE 2 "ON OPEN":
If the photocell is engaged during opening, it stops the gate until
disengagement (re-starts opening). The photocell is not activated during
closing.
RX PHOTOCELL TYPE 3 "ON OPEN+CLOSE":
If the photocell is engaged during opening, it stops the gate until
disengagement (re-starts opening). If the photocell is engaged during
closing, it runs a full inversion (opening) cycle.
RX PHOTOCELL TYPE 4 "IN STOP":
If the photocell is engaged during opening or closing, it permanently stops
the gate (also with automatic closing enabled). The user will have to send a
subsequent command to restore operation of the automation.
OPERATION TYPE 1
OPERATION TYPE 2
OPERATION TYPE 3
OPERATION TYPE 4
OPER.
OPER.
OPER.
TYPE 2
TYPE 3
TYPE 4
ON OPEN
ON OPEN +
IN STOP
CLOSE
[OPEN]
[AUTO-PP]
-
[CLOSE]
[STOP]
In =
In =
In =
[OPEN]
[AUTO-PP]
[AUTO-PP]
[CLOSE]
[STOP]
[PED]
Out = AUX
Out =
Out =
INDICATOR
INDICATOR
LIGHT
LIGHT
-
-
-
DART