4 – English
?
Manual procedure
paragraph 5.3
Semi-automatic procedure
paragraph 5.4
?
Manual procedure
paragraph 5.3
Semi-automatic procedure
paragraph 5.4
Semi-automatic procedure
paragraph 5.4
option
"FTC"
(paragraph 5.7)
Semi-automatic procedure
paragraph 5.4
"FTA" option (
)
paragraph 5.8
position "0"
5
function "RDC"
position "2"
(function "FRT")
manoeuvre (to set the required torque value, refer to paragraph 5.5).
This function is always enabled and can only be disabled during semi-automatic pro-
gramming of the limit switches (see paragraph 5.4).
5.3 - Programming limit positions "0" and "1" MANUALLY
Caution!
- This programming mode is recommended for vertical blinds and awnings
without boxes.
- The RDC function cannot be enabled in these cases.
01. Press and hold the pushbutton (Up or Down) to move the awning to the point of
mid-travel. Note - during movement, 2 brief interruptions indicate that no limit
position is memorised.
02. Press and hold the Up pushbutton until the awning moves to the required limit
position, then release the button.
03. Press and hold the two Up and Down pushbuttons simultaneously until the
motor has completed a short down movement, then release.
04. Press and hold the Down pushbutton until the awning moves to the required lim-
it position, then release the button. Note - during movement, 1 brief interruption
indicates that only one limit position is memorised.
position "1"
position "S"
(function "FTC")