Maintenance And Troubleshooting - T.I.P. HWW 6000 EPF Manual De Instrucciones

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

You can now check the pre-pressure on the boiler valve using a commercially
available air pressure gauge. This pressure must be 1.5 bar and must be cor-
rected if necessary.
If water escapes from the tank valve, the diaphragm is defective and must be re-
placed. A high-quality diaphragm is available as a spare part.

9. Maintenance and troubleshooting

Prior to carrying out any maintenance work, the pump must be sepa-
rated from the electrical mains. If you fail to separate the unit from
mains, there is a risk of an inadvertent start of the pump.
We decline any liability for damage caused by inappropriate repair at-
tempts. Any damage caused by inappropriate repair attempts will avoid
all warranty claims.
Regular maintenance and thorough care will reduce the danger of possible malfunc-
tion and contribute to an extension of the lifetime of your unit.
If the pump is to be put out of operation for some extended period of time, it should
be emptied completely in by opening the water drain screw (10). Subsequently,
please flush the pump with clean water. Then allow the pump body to dry completely
in order to prevent corrosion damage.
Water left in the pump may freeze in case of frost and thus cause considerable
damage. Please store the pump in a dry, frost- protected place.
In the case of malfunction, you should first of all check whether it was caused by an
operating error or some other reason which cannot be attributed to a defect of the
device - for instance a power failure.
The list below shows some possible malfunctions of the device, possible causes and
tips on their elimination. All the measures referred to may only be carried out with the
pump being separated from the electrical mains. If you yourself feel unable to elimi-
nate any of these malfunctions, please contact the customer service department or
your point of sales. Any repair beyond the scope specified below must only be per-
formed by qualified staff. Please bear in mind that all warranty claims will become
void in the case of damage caused by inappropriate repair attempts, and that we de-
cline any liability for any ensuing damage.