1
2
3
4
5
4.8 Electrical projection screens with built-in RF receiver
•
Connect a plug (not included) and plug it into the socket.
Warning! Projection screens with a built-in remote control must be
connected to the electric mains using a plug. The plug must be easily
accessible to ensure that the projection screens can be made voltage-free if
necessary.
Warning! If the projection screens has a fixed connection to the electric
mains a switch must be fitted to ensure that the projection screen can be
made voltage-free. This switch must be suitable for use in combination with
the electric mains. The contact opening between the switch points must be
at least 3 mm.
4.9 Built-in RF receiver and remote control
Insert the battery before use as described in § 7.3
➊
Up button
Allows the projection screen to retract.
➋
Stop button
Stops unrolling/retracting.
➌
Down button
Allows the projection screen to unroll.
LED
➍
Illuminates to confirm a command.
➎
Program button
- Deletes program from remote control.
- Programs new (additional) remote control.
When the program button is used, the motor will confirm with a 'beep'. A series of
beeps will confirm when a new setting is accepted.
Programming an additional (second) remote control or wall transmitter
You can program an additional RF remote control or wall transmitter for operating
the projection screen.
➊
Press the program button twice (2x) on the original remote control.
➋
Press the program button once (1x) on the extra remote control.
Deleting the program of a remote control
➊
Press the program button once (1x).
➋
Press the stop button once (1x).
➌
Press the program button once (1x).
The program is now deleted.
Programming a new remote control after losing the original
remote control.
➊
Power off the motor.
➋
Power on the motor.
➌
Press the program button twice (2x).
➍
Press the down button once (1x).
EN
11