DRYER DIMENSIONS
(112.0 cm)
ALCOVE OR CLOSET REQUIREMENTS
MINIMUM CLEARANCES
•
Dimensions shown are the recommended minimum clearance allowances.
•
Space on the sides of the dryer is required to avoid noise transfer.
•
Space 5" (12.7 cm) at the rear of the dryer is necessary to accommodate exhaust
ducting.
OTHER REQUIREMENTS
•
This dryer must be vented to the outdoors.
•
Do not install the dryer in a closet with a solid door.
•
A closet door must be louvered or vented with a combined minimum of 72 sq. in.
(465 sq. cm.) with a minimum clearance of 3" (76 mm) at the top and bottom. The
airflow must not be obstructed in any way.
•
No other fuel-burning appliance shall be installed in the same closet as the gas
dryer.
44.2"
30.8"
(78.2 cm)
1"
(2.5 cm)
60 in.
2
(387.1 cm
)
2
60 in.
2
(387.1 cm
)
2
27"
(68.6 cm)
3"
11"
(76 mm)
(29.7 cm)
5"
(12.7 cm)