TROUBLESHOOTING
ERROR CODES
When the dryer senses an error all machine operations will stop, a series of 4 beeps
will sound and an error code will be shown in the Estimated Time Remaining display.
ERROR CODE
C9
(Short Circuit)
E4
(Heating Element
Problem)
E5
NORMAL OPERATING SOUNDS
•
The following sounds are normal during the operation of the dryer.
•
Tumbling sound: This is normal as the heavy, wet clothes in the dryer are
continuously being tossed around.
•
Air rushing noise: This happens as the dryer drum spins and the air is rushing
through the dryer drum.
DRYER DOES NOT OPERATE
•
Check that the dryer is plugged in. The plug may have come loose.
•
Check that the electrical wall receptacle is of proper voltage. Electric dryers
require a 240 volt power supply.
•
Check if the circuit breaker needs to be reset, or if the fuse needs to be replaced.
•
Check that the dryer door is firmly closed.
•
Press the Start/Pause button again if the door is opened during the cycle.
DESCRIPTION
The PCBs failed.
The humidity sensor failed.
The temperature sensor failed.
POSSIBLE CAUSE AND SOLUTION
Call for service.
The unit will complete the
current operating cycle.
The unit can still operate under
the Time cycles.
Call for service.
Call the service center for help.
31