Beko DRYPOINT MD Premium Serie Instrucciones De Instalación Y Servicio página 2

4
5
2
English
1. Liability for material defects
Please read the following information carefully.
Liability for material defects can only be assumed if these
instructions are observed and the installation instructions are
followed.
If the intended CLEARPOINT
elements are replaced annually, the compressed air membrane
dryer is entitled to rectification of material defects for a period
of 2 years from the invoice date.
BEKO shall not be liable for damage resulting from inappropri-
ate handling, wear, storage or other actions of the purchaser
or third parties.
This applies in particular to wear parts.
2. Temperature
The unit must be installed in a room that is protected against
frost. The ambient temperature as well as the compressed air
temperature must be between +36 and +140 °F.
2
Important information • Indicaciones importantes
5
5
3
8
filters are used and the filter
®
4
5
5
1
3 : Integrated filter
Filtro integrado
Filtre intégré
Filtro integrado
3. Filter
Observe the filter requirements (see pages 8 - 9):
Particles, oil components and liquid condensate must be
safely retained.
For this, a CLEARPOINT
the housing of the membrane dryer. In case of high dirt load
or heavy condensate accumulation, additional ultra-fine filters
(0.01 µm) and, if necessary, preliminary filters (5 µm) must be
used (see page 12).
Caution: Exchange filter elements annually.
Caution: Only carry out service measures when the device
is pressureless.
This also includes changing the filter integrated in the mem-
brane dryer:
- Loosen the lower part of the housing (fine thread), while
holding the housing profile of the membrane dryer in place
- Inspect float drain and replace if necessary (FAD055)
- Replace filter element and retighten housing
4
5
filter S (0.01 µm) is integrated in
®
DRYPOINT
MD premium series
®
loading

Este manual también es adecuado para:

Drypoint mdp 2Drypoint mdp 4Drypoint mdp 6Drypoint mdp 8