Installation Instructions – Galleon II Area Site and Flood
Upswept Arm (UP) (Fig. 9)
Tools Required:
Ratchet with 9/16" and 3/4" sockets
#2 Phillips head screwdriver
1.
Remove the pole top cap.
2.
Loosen (1) #8 screw to remove the access cover from
the arm. Rotate down, sliding the cover rearward to
disengage from the front slots.
3.
Install and hold the provided nut plate inside the pole.
Install (1) 1/2"-13 fastener through the adapter, pole and
into the nut plate, and hand-tighten. Insert the lower
1/2"-13 fastener, keeping loose to ensure alignment
while tightening the upper mount. Tighten the upper
flange bolt to arm bracket and pole to 40 ft-lbs.
(54 N-m.)
4.
Remove the lower 1/2"-13 fastener and position fixture
over adapter bracket. The quick mount arm will engage
the slot on the adapter bracket to secure the fixture.
With the fixture supported, reinstall the lower 1/2"-13
fasteners and hand-tighten.
5.
Install the 3/8"-16 fastener through the arm bracket
into the arm. Hand-tighten to ensure alignment, then
tighten the ½"-13 lower flange bolt to 40 ft-lbs. (54
N-m.) Tighten the 3/8"-16 upper flange bolt to 20 ft-lbs.
(27 N-m.).
6.
Route the fixture leads through the center opening of
the nut plate, pole and arm into the arm cavity.
7 .
Attach the supply side ground wire to the ground
terminal connector (green wires).
8.
Connect the supply side line voltage wire to the fixture
side line voltage terminal connector (black wires).
9.
Connect the supply side neutral wire to the fixture side
neutral wire terminal connector (white wires).
10. Insert the access cover by inserting the tabs into the
front arm slots. Tighten the (1) #8 screw to 14 in-lbs.
11. Replace pole top cap.
6
Cooper Lighting Solutions
IB500157EN
Installation instructions
Bracket Arm
M Pattern Nut
Plate
Customer
Pole
3/8-16
Flange Bolt
Figure 9.
Photocontrol Orientation (If Equipped – Fig 10.)
N
ote:
If your luminaire is equipped with a photocontrol
receptacle, see IB525002EN Photocontrol
Receptacle Supplement to identify your photocontrol
and follow the instructions on the diagram and all
applicable notes
Bi-Level Switching (If Equipped)
For Bi-level switching, the input leads to the fixture will be
independently labeled to indicate dimming preferences as
appropriate (as defined by the order requirements). Two
separate supply lines of line voltage, neutral and ground
must be connected to the fixture leads to enable the bi-level
switching functionality of the fixture.
Maintenance
A regular maintenance schedule should be followed to
retain optimal light output and thermal performance. Optical
lens cleaning should be performed with a clean dry cloth to
remove any dust or other contaminants. Additional cleaning
can be performed with non-abrasive acrylic cleansing
solution.
Photocell Receptacle
Figure 10.
Access Door
Swept Arm
2X - 1/2-13 Flange Bolts
Lock Tabs
Access Cover
#8 Screw