Pole Mount, Adjustable (PA) (Fig. 3)
Tools Required:
Ratchet with 3/4" socket
#2 Phillips head screwdriver
1.
Loosen (3) #8 screws to remove the access cover from
the arm.
2.
Ensure the pole is drilled for a "N" pattern. A template
may be provided as required.
3.
Remove the pole top cap.
4.
If using the optional round pole adapter install that
between the luminaire and round pole. For square
poles, this is not required.
5.
Install and hold the provided nut plate inside the pole.
With the fixture supported, align (2) 1/2-13 fasteners
through the arm, pole adapter if used and hole pattern
in pole into the nut plate. Hand tighten to ensure the
fixture is aligned prior to tightening.
6.
Tighten both flange bolts within the fixture to 40
ft-lbs./54 N-m.
7 .
Route the fixture leads through the center opening of
the nut plate, pole and arm into the arm cavity.
8.
Inside the fixture arm, connect supply wires to
appropriate fixture leads:
a.
Supply side ground wire to green fixture lead.
b.
Supply side neutral wire to white fixture lead.
c.
Supply side line voltage wire to black fixture lead.
9.
Loosen the (2) 3/8-16 located in the slots to make angle
adjustments to the fixture. After angle adjustments
have been made using the (2) 3/8-16 flange bolts
located in the slots. Tighten and torque to 20 ft-lbs
10. Replace the access cover to the arm. Tighten the (3) #8
screws and torque to 12~14 in-lbs.
Nut Plate
Round Pole Adapter
Access Cover
3X-#8 Screw
Figure 3.
Installation Instructions – Galleon II Area Site and Flood
Center Wire Way
2X Adjustment Bolt Do Not
Remove
2X-1/2-13 Flange Bolt
Washer Plate Ensure B Arrow Is
Facing Down
Wall Mount, Fixed (WM) (Fig. 4)
Tools Required:
Ratchet with 3/4" socket
#2 Phillips head screwdriver
1.
Loosen (2) #8 screws to remove the access cover from
the arm. Rotate down, sliding the cover forward to
disengage from the rear slots.
2.
Align the center holes in the decorative wall plate to
the fixture arm. Use the (2) 1/2"-13 fasteners and hand-
tighten, ensuring proper alignment.
3.
Tighten the (2) 1/2"-13 fasteners to 40 ft-lbs. (54 N-m.)
Set the fixture assembly aside.
4.
Thread supply wires from the junction box through the
wall gasket, and through the center opening of the
attachment plate.
5.
Secure attachment plate to the wall using four bolts
(supplied by others.)
6.
Thread the supply wires through the center opening
of the decorative wall plate and into the arm assembly
(passing through the silicone rubber wire grommet.)
7 .
Hang the decorative wall plate onto the attachment
plate and tighten the 1/4-20 screw located at the
bottom of the decorative wall plate to 15 in-lbs.
8.
Inside the fixture arm, connect supply wires to
appropriate fixture leads:
a.
Supply side ground wire to green fixture lead.
b.
Supply side neutral wire to white fixture lead.
c.
Supply side line voltage wire to black fixture lead.
9.
Insert the access cover by inserting the tabs into the
rear arm slots and close the cover. Tighten the (2) #8
screws to 14 in-lbs.
4 SQ, 6 SQ AND 9 SQ Housing
Decorative Wall Plate
Wall Plate
(Hardware
Supplied by
Customer)
Wall Gasket
Figure 4.
Cooper Lighting Solutions
2X - 1/2-13 Fastener
2X - #8 Fastener
Access Cover
1/4-20 Fastener
IB500157EN
Installation instructions
Luminaire
Access Door
3