Exhaust Filter - Siemens VS Q8 Instrucciones De Uso

Ocultar thumbs Ver también para VS Q8:
Tabla de contenido
Cleaning the foam filter
If your appliance is fitted with a filter frame and foam
filter, the foam filter should be cleaned at regular inter-
vals by tapping out the dust.
20*
Fig.
Open the dust bag compartment lid.
Pull out the filter frame and foam filter in the direc-
tion of the arrow.
Remove the foam filter from the filter frame and
clean it by tapping out the dust.
After cleaning, place the foam filter back in the filter
frame, insert the filter frame with foam filter in the
appliance and close the dust bag compartment lid.
!
Caution: The vacuum cleaner must not be operated
without the motor protection filter.
Exhaust filter
The exhaust filter must be cleaned or replaced at least
once a year.
Replacing the micro-hygiene exhaust filter
21*
Fig.
Open the rear flap.
Unlock the filter holder by moving the locking tab in
the direction of the arrow.
Remove the foam filter* from the filter holder and
tap it out.
Replace the old micro-hygiene filter with a new one.
(This is included in the filter pack when you purchase
original dust bags).
Insert the foam filter into the filter holder.
Insert the filter holder into the appliance and lock it
in place.
Cleaning the (H)EPA* exhaust filter
The (H)EPA* filter is designed so that it does not need
to be replaced, provided the appliance is used as inten-
ded in the household.
To ensure that the vacuum cleaner is working at its op-
timum power level, the (H)EPA* filter should be rinsed
out after one year. The filtering action of the filter re-
mains intact, even if the filter surface becomes disco-
loured.
Fig.
17
Fig.
After vacuuming fine dust particles (e.g. gypsum, ce-
ment, etc.), clean the motor protection filter by tapping
it out or, if necessary, replace the motor protection fil-
ter and exhaust filter.
Care
Always switch off the vacuum cleaner and disconnect
the power cord from the mains before cleaning the va-
cuum cleaner. The vacuum cleaner and plastic acces-
sories can be cleaned with an ordinary plastic cleaner.
!
The dust compartment can, if necessary, be cleaned
with a second vacuum cleaner or simply wiped with a
dry cloth or dusting brush.
Subject to technical modifications.
* Depending on model
22*
Open the rear flap.
Unlock the (H)EPA* filter by moving the locking tab
in the direction of the arrow, and remove it from the
appliance.
Tap out the filter unit and rinse it under running wa-
ter.
Alternatively, the unit can be cleaned in a washing
machine at max. 30 °C using a gentle programme and
the lowest spin speed.
TIP: To protect other laundry items, put the filter
unit into a laundry bag.
Once the (H)EPA* filter has dried completely (at
least 24 hours), insert it back into the appliance and
lock it in place.
Close the rear flap.
Do not use abrasive materials, glass-cleaning agents
or all-purpose cleaning products. Never immerse the
vacuum cleaner in water.
31
Tabla de contenido
loading

Tabla de contenido