Technical Data - YATO YT-73094 Manual Original

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
DESCRIPTION
A multifunctional meter is a digital measuring instrument designed to measure various electrical or physical quan-
tities. The meter has a plastic casing, liquid crystal display, and a range/measured quantity switch. The casing has
measurement jacks fi tted. The meter comes with test leads terminated with plugs. The meter is sold without a battery.
Before using the meter, read the instruction manual in its entirety and keep it for later use.
CAUTION! This meter is not a measuring instrument within the meaning of "the Trade Metrology Act".

TECHNICAL DATA

Display: 4 digits LCD – maximum displayed result: 9999
Sampling frequency: approx. 2–3 samples per second
Overload marking: "OL" symbol displayed
Polarity marking: "–" sign displayed before the result
Battery: 2 x AAA (2 x 1.5 V)
Fuse: F630mAH250V (fast-acting); F10AL250V (fast-acting)
Working temperature range: 0 to 40
Temperature at which the declared accuracy is maintained: 18 to 28
Storage temperature: -10
Outer dimensions: 150 x 70 x 50 mm
Weight (without batteries): 195 g
CAUTION! It is forbidden to measure electrical values exceeding the maximum measuring range of the meter.
DC voltage
Range
Resolution
999.9 mV
100 μV
9.999 V
1 mV
99.99 V
10 mV
600 V
100 mV
Overload protection:
600 V DC or 600 V AC RMS
Alternating current
Range
Resolution
999.9 μA
9999 μA
99.99 mA
600 mA
10 A
Overload protection: μA/mA range - 630mA/250 V fuse; 10
A range: 10A/250 V fuse. Max. input current mA connector:
600 mA; 10A connector: 10A. Frequency of the measured
signal: 45 ÷ 1000 Hz.
O R I G I N A L
C at relative air humidity <70%
o
C to +50
C at relative air humidity <85%
o
o
Accuracy
±(0.7% + 3)
±(0.8% + 2)
Accuracy
0.1 μA
1 μA
±(1.0% + 3)
0.01 mA
0.1 mA
0.01 A
±(1.5% + 3)
GB
C at relative air humidity <70%
o
Range
0.999 V
9.999 V
99.99 V
600 V
True RMS measurement for input impedance approx. 10 MΩ.
Frequency of the measured signal 45 ÷ 1000 Hz. Maximum input
voltage 600 V AC. (eff ective value)
Range
999.9 μA
9999 μA
99.99 mA
600 mA
10 A
Overload protection: μA/mA range - 630mA/250 V fuse; 10
A range: 10A/250 V fuse. Max. input current mA connector:
600 mA; 10A connector: 10A
I N S T R U C T I O N S
AC voltage
Resolution
Accuracy
0.001 V
0.01 V
±(1% + 3)
0.1 V
0.1 V
±(1.2% + 3)
Direct current
Resolution
Accuracy
0.1 μA
1 μA
±(0.8% + 3)
0.01 mA
0.1 mA
0.01
±(1.2% + 3)
11
Tabla de contenido
loading