YATO YT-73094 Manual Original página 12

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 62
Resistance
Range
Resolution
999.9 Ω
9.999 kΩ
0.001 kΩ
99.99 kΩ
0.01 kΩ
999.9 kΩ
9.999 MΩ
0.001 MΩ
9.99 MΩ
0.01 MΩ
Continuity test/LED test
Open circuit voltage 3.3 V
NCV - non contact alternating voltage
Range
Low fi eld
High fi eld
Accuracy: ±(% of indication + weight of the least signifi cant digit)
OPERATION
CAUTION! To avoid the risk of electric shock, disconnect the test leads and switch off the meter before opening the
casing.
Safety instructions
Do not operate the meter in an atmosphere with excessive humidity or in the presence of toxic or fl ammable vapours,
or in an explosive atmosphere. Before each use, check the condition of the meter and the test leads. If you notice
any faults, do not start its operation. Replace damaged cables with new ones, devoid of defects. In the case of any
doubts, you should contact the manufacturer. During measurement the test leads should be held by the insulated
parts. Do not touch the measurement points or unused measuring jacks of the meter. Disconnect the test leads before
changing the measured quantity. Never carry out maintenance work without ensuring that the test leads have been
disconnected from the meter and that the meter itself has been switched off .
Replacing the battery
The multimeter requires batteries, the number and type of which are specifi ed in the technical specifi cations. It is rec-
ommended to use alkaline batteries. To install a battery, open the instrument casing or the battery compartment cover
on the underside of the meter. Before accessing the battery compartment it may be necessary to slide off the cover of
the meter casing. Connect the battery according to its terminal marking, close the casing or battery compartment cov-
er. If a battery symbol appears on the screen, the battery must be replaced. For the sake of measurement accuracy,
it is recommended to replace the battery as soon as possible after the battery symbol appears.
Fuse replacement
The instrument uses a fast-acting safety fuse. In case of damage, replace the fuse with a new one with identical
O R I G I N A L
12
Accuracy
0.1 Ω
±(1.0% + 2)
0.1 kΩ
±(2.0% + 4)
Description
Indication "L", NCV indicator lights up
green, buzzer emits a sound signal
Indication "H", NCV indicator lights
up red (two LEDs), buzzer emits a
sound signal
GB
Range
9.999 nF
99.99 nF
999.9 nF
9.999 μF
99.99 μF
999.9 μF
9.999 mF
99.99 mF
Range
10 Hz – 60 kHz
Range
1.5 V
9 V
I N S T R U C T I O N S
Capacitance
Resolution
0.001 nF
0.01 nF
0.1 nF
0.001 μF
0.01 μF
0.01 μF
0.001 mF
0.001 mF
Frequency
Resolution
0.01 Hz – 0.01 kHz
Battery test
Description
The load resistance is approx. 30 Ω, the
indicator shows the battery voltage
The load resistance is approx. 300 Ω, the
indicator shows the battery voltage
Accuracy
±(4.0% + 30)
±(4.0% + 3)
±(5.0% + 30)
Accuracy
±(1.0% + 4)