BTL5-D1_ _-M_ _ _ _-P-S93
Micropulse Linear Transducer in Profile Housing
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Proper application
The BTL5 Micropulse transducer is
intended to be installed in a machine
or system. Together with a controller
(PLC) or a master it comprises a posi-
tion measuring system and may only
be used for this purpose.
Installation
Ensure that no strong
electrical or magnetic
fields are present in the
immediate vicinity of the trans-
ducer.
Any orientation is permitted.
Mount the transducer on a level
surface of the machine using the
mounting brackets. Observe the
recommended spacing of the
mounting brackets.
The floating magnet is attached to
the moving member of the machine
using non-magnetizable screws
(brass, aluminum). To ensure the ac-
curacy of the transducer system,
the moving member must carry the
magnet on a track parallel to the
transducer.
Permissible values for distance and
center offset are indicated in the
drawing.
User's Manual
A detailed user'manual and con-
figuration guide for this trans-
ducer can be obtained at
using the
link Micropulse Transducers,
User's Manuals ..... E-mail re-
quests can be made to
DIP switches S1 for
setting configuration
Mounting brackets with isolation bushings and M5 x 22 cylinder head screws, DIN 912, max. tightening torque 2 Nm
Wiring
System and control cabi-
net must be at the same
ground potential.
Pin BTL5-D1...S93
Data signals DeviceNet
Bus In / Bus Out
1
Shield
2
V+
3
V- (GND)
4
CAN_H
5
CAN_L
Supply voltage (external)
Power
➀
1
+24 V
3
0 V (GND)
4
Shield
➀
Please note that 24 V must be
supplied and not 5 V for the
CAN driver.
Configuration
MAC ID:
Values from 0...63 allowed
S1.1 S1.2 S1.3 S1.4 S1.5 S1.6
2
0
2
1
2
2
2
3
LSB
1
2
4
8
Values of 0...3 can be set by using
S1.8...S1.9.
S1.8 S1.9
0
1
2
2
LSB MSB
1
2
Bus termination S1.10 = ON
Nominal stroke = Measuring range
BTL5-P-3800-2
➁
magnet
Startup
Observe all relevant safety regula-
tions!
Check connections: Components
can be damaged by improper con-
nections and overvoltage. Verify all
connections before applying power!
Turning on the system: Note that the
system may execute uncontrolled
movements when the transducer is
part of a closed-loop system whose
parameters have not yet been set.
Therefore make sure that no hazards
could result from these situations.
Check functionality: The functional-
ity of the transducer system and all its
associated components should be
regularly checked and recorded. In
particular, steps must be taken to
ensure that should the transducer
system become defective no hazards
to persons or property can result.
Fault conditions: When there is evi-
dence that the transducer system is
not operating properly, it should be
taken out of service and guarded
against unauthorized use.
Connector
straight:
right-angle: BKS-S93-00 / S95-00
S1.7
Cable with connector
2
4
2
5
INT
MSB
16
32
DIP-ID
Baud rate [kBaud]
3
internal
2
500
1
250
0
125
➁
not included
UL authorization
File No.
E227256
➁
for Bus In / Bus Out:
BKS-S92-00 / S94-00
➁
for Power:
BKS-S 48-15-CP-_ _
Power (male)
(female)
(male)
1
english