Intended use
The device is to be used for starting up vehicles
with an on-board voltage of 12 V or 24 V if the
start-up capacity of the vehicle batteries is insuffi-
cient. In addition it can be used to replace defective
on-board 12 V and 24 V batteries in order to start
up the engine!
Any other use is considered an improper use.
The user is solely responsible for damage
resulting from improper use.
Operation (fig. I)
Connection and start-up
Note
Charge the device for 24 hours before
using it for the first time!
Caution
Reverse connection protection is only
active when the battery voltage > 4 V.
Make sure the device is switched off.
■
First connect the cables with the red booster
■
cable clamp to the positive pole of the battery.
Connect the cable with the black booster cable
■
clamp to the negative pole of the battery.
When connecting the booster cable clamps
■
ensure good contact and secure fit.
Switch on the device.
■
10
LED indicator
Display
Status
Reverse connec-
Disconnect the booster cable
tion indicator [11]
clamps, interrupt start-up
shows red
procedure
Reverse charge
Booster cable is not connected.
indicator [11] not
Vehicle battery voltage is less
illuminated
than 4 V or vehicle battery is
missing altogether.
Reverse charge
Start-up procedure, press the
indicator [11]
ON button [1]
illuminated green
Charge level LEDs
Start-up procedure
[2] and [10] light
green
Charge level LEDs
Start-up procedure with
[2] and [10] light
reduced start-up capacity
orange
Charge level LEDs
Battery voltage too low
[2] and [10] light
red
Automatic jump start
Use this function for start-up with the vehicle batteries
in place. It helps to make best use of the extreme
start-up capacity of the battery booster kit.
Check LED [8] ; if LED is not lit, automatic start is
■
not possible.
Press the AUT button [9] .
■
3 LED [8] is lit green; device is ready for opera-
tion.
3 The engine can be started; the start-up voltage is
then switched on automatically.
3 If the clamps are energised, the LED [4] or [7]
is lit red!
Note
If you are not sure about the automatic
voltage selection, check the on-board
voltage and choose the voltage
manually. This can be done anytime
by pressing the buttons 12 V [5] or
24 V [6] .
3 After 6 seconds the start-up procedure is auto-
matically stopped.