Field setting mode
Space Heating : Code 40
T s
DHW by Booster Heater Only
DHW by Booster Heater Only
#3034
T u
Main Menu &
Sub Menu Function
Code
Heating Code
Heat Pump
40
Backup Heater
Backup Boiler
Mixing valve
Inverter Pump
#4012
Description
Heating/DHW Priority
Outdoor Temp for Priority
Heating O
Overshoot
Application
BUH/BSH Priority
Cold weather compensation
Threshold Temp
Defrost Backup Temp.
Application
Boiler Priority
Threshold Temp
Application
Target T(Heating)
Target T(Cooling)
Control factor
Control interval
Running Time
Application
Target T
Control factor
T a
Field Setting Value
Sub Code
11
12
13
14
21
22
23
24
25
31
32
33
41
42
43
44
45
46
51
52
53
ENGLISH-46
Default
Min
Max
0(DHW)
0
1(Heating)
0
-15
20
35
14
35
2
1
4
0(No)
0
1(Yes)
0(Both)
0
2(BSH)
1(Yes)
0(No)
1
0
-15
35
15
10
55
0(No)
0
1(Yes)
0(No)
0
1(Yes)
-15
-20
5
0(No)
0
2
10
5
15
10
5
15
2
1
5
2
1
30
9
6
24
1(Yes)
0
1(Yes)
5
2
8
2
1
3
Step Unit
-
-
1
˚C
1
˚C
1
˚C
-
-
1
-
-
-
1
˚C
5
˚C
-
-
-
-
1
˚C
1
-
1
˚C
1
˚C
1
-
1
min
(x10)
3
sec
-
-
1
˚C
1
-