Additional technical data
Operating voltage
12 V (DC/AC)
Power consumption with sound
0.65 A (DC) / 0.91 A (AC)
Power consumption without sound
0.63 A (DC) / 0.90 A (AC)
Fuse
1.25 AT (slow)
(Repairs may only be carried out by an expert!)
Weight
approx. 5.2 kg
Approval
The front case with flame effect is included in the
Trumatic S 5002 heater approval. The CE product
identification number of the heater remains the same.
The right to effect technical modifications is reserved!
Supplement to Trumatic S 5002
installation instructions
Important installation instructions
The inner installation box of heaters that were installed prior
to 03/2004 must be replaced when changing to the front case
with flame effect.
In order to ensure that the heater works correctly and avoid
subsequent rattling noise from the heat exchanger and the
heater front case, the dimensions on the heater installation
template must be adhered to exactly.
The Trumatic S 5002 heater and the front case with flame ef-
fect are designed for standard right-hand installation. The con-
trol panel must be moved to the right-hand side of the front
case with flame effect if left-hand installation is required.
12 V
To do this, detach cable from control panel, push both catches
together and remove control panel. Push control unit into
right-hand side. Then route cable along right-hand side of
front case to control panel as shown in figure.
4
Electrical connection 12 V
Electric cables, switching units and control units for heaters
must be arranged in the vehicle in such a way that their satis-
factory operation cannot be adversely affected under normal
operating conditions. All cables leading to the outside must be
splash proof at the leadthrough opening.
Prior to working on electric components the appliance
must be disconnected from the power supply. Switch-
ing off at the control panel is not sufficient!
Connect device to fuse-protected on-board power supply (5 A
central electrical system) with provided cable (1.5 m). The po-
larity is not important.
No other consumers must be connected to the supply line!
When power supplies are being used, it must be noted
that the output voltage is between 11 V and 15 V and the
alternating current ripple is < 1.2 Vss.
Route 12 V supply line along the floor towards the rear and at-
tach to the heater pedestal using the provided clip.
Fitting the front case
Connect 12 V supply line to electronic system (connect plug
so that both plug wires are routed downwards). Engage sup-
ply line in clip (d) at bottom of front case. Fit front case as
shown in the installation instructions supplied with the heater.
+ 12 V
d
12 V