X8
Specifications
Channel Handling
Number of output channels
Number of input channels:
Analog
AES3
Dante™*
* DANTE version only
Audio
Output Noise
A-Weighted @ 8 Ω - Analog to Analog / Digital to Analog
Dynamic Range
A-Weighted @ 8 Ω - Analog to Analog / Digital to Analog
Damping Factor @ 8 Ω, 20Hz - 500Hz
Slew Rate (input filter bypassed)
Frequency Response ( -3 dB , 1 W @ 8 Ω)
Crosstalk (1 kHz)
THD+N (from 0.1 W to Full Power)
DIM (from 0.1 W to Full Power)
Input Impedance
Input Acceptance
DSP
AD converters
DA converters
Sample rate converter
140 dB Dynamic Range - 0.0001 % THD+N
Internal precision
Delay
up to 100 ms per output for time alignment
Raised-cosine, custom FIR, parametric IIR:
Equalizer
Linear phase (FIR), hybrid (FIR-IIR), Butterworth, Linkwitz-Riley,
Crossover
Limiters
TruePower™, RMS voltage, RMS current, Peak limiter
Damping control
Construction
Dimensions
483 mm x 89 mm x 495 mm (19.0 in x 3.5 in x 19.5 in)
Weight
8 mono,
bridgeable per ch. pair
8 (8x XLR)
8 (4x XLR)
16 (2x RJ45)
< -70.0 dBV
114,3 dB
> 5000
> 50 V/µs
5 Hz - 30 kHz
-70 dB
< 0.5%
(typical < 0.01%)
< 0.5%
(typical < 0.01%)
20 kΩ Balanced
+27 dBu
Dual 24 bit 48 kHz Tandem
architecture
®
with 129 dBA of dynamic range
Dual 24 bit 48 kHz Tandem
architecture
®
with 121 dBA of dynamic range
24 Bit @ 44.1 kHz to 192 kHz
40 bit floating point
up to 2 s on input section
peaking, hi/lo-shelving, all-pass,
band-pass, band-stop, hi/lo-pass
Bessel: 6 dB/oct to 48 dB/oct (IIR)
Active DampingControl™
24 kg (52.9 lb)
Output Stage
Maximum output power per channel @ 8 Ω
Maximum output power per channel @ 4 Ω
Maximum output power per channel @ 2.7 Ω
Maximum output power per channel @ 2 Ω
Maximum output power @ 8 Ω Bridged
Maximum output power @ 4 Ω Bridged
Peak total output, all channels driven
Maximum unclipped output voltage
Maximum output current
The power figure is calculated by driving and loading symmetrically all the
channels: uneven loads allow to achieve highest performance.
AC Mains Power
Single-Phase
Nominal Voltage
Operating Range
Power Factor
1/8 Maximum Output Power @ 4 Ω
Current Draw
1/8 Maximum Output Power @ 4 Ω
Suggested circuit breaker
Three-Phase
Nominal Voltage**
Power Factor
1/8 Maximum Output Power @ 4 Ω
Current Drawn from Each Single Phase
1/8 Maximum Output Power @ 4 Ω
Suggested circuit breaker (per phase)
Bi-Phase
Nominal Voltage
Idle Consumption (all AC MAINS cases)
Max Consumption (all AC MAINS cases)
** Note: 208Y/120 V = 208 V phase-to-phase, 120 V phase-to-neutral
Thermal
Operating temperature
Cooling
Thermal dissipation
Single phase
1/8 Maximum Output Power @ 8 Ω
1/4 Maximum Output Power @ 8 Ω
1600 W
3000 W
4000 W
5200 W
6000 W
10400 W
40000 W
175 V
peak
130 A
peak
100 - 240 V @ 50/60Hz
90 - 264 V from DC to 200Hz
> 0.9
32 A
18 A
rms
rms
@ 100V
@ 240V
C32
208Y / 120 - 416Y / 240 V, 3~, 3W+N+PE
@ 50/60Hz
200 V~, 3W+PE @ 50/60Hz
> 0.9
12 A
6 A
rms
rms
@ 208Y
@ 416Y
C16
200/100 V, 2W+PE @ 50/60Hz
< 200 W
< 5000 W
0° - 15°C / 32° - 113°F
Fan, continuously variable
speed, teperature controlled
115V
230V
2117 BTU/h
1946 BTU/h
3892 BTU/h
2875 BTU/h
Specifications | 101