AIR COMPRESSOR - DIRECT DRIVE
INSTALLATION
INSTALLATION
5. Grounding Instructions:
This product should be grounded. In the event of an electric short circuit, grounding
!
reduces the risk of electric shock by providing an escape wire for the electric current. This
product is equipped with a cord having a grounding wire with an apropriate grounding plug.
The plug must be plugged into an outlet that is properly installed and grounded in
accordance with all local codes and norms.
5.1 Warning
Improper installation of the grounding plug can result in a risk of electric shock. If repair or
!
replacement of the wire or plug is necessary, do not connect the grounding wire to either flat
blade terminal. The wire with insulation having an other surface that is green with or without
yellow stripes is the grounding wire. Check with a qualified electrician or serviceman if the
grounding instructions are not completely understood, or if in doubt as to whether the
product is properly grounded. Do not modify the plug provided; if it does not fit the outlet,
have the proper outlet installed by a qualified electrician.
6. Cabinet's installation procedure:
6.1
Before connecting the cabinet to the electric suplly, check if the indicated voltage in the
input wire tag is the same as the voltage indicated in the compressor.
6.2
Lift the cabinet.
6.3
Place it over the compressor.
6.4
Lower it toward the compressor until it touches the flor. Check that the rear lid of the electric
motor perfectly fits the left side hole of the cabinet's internal part.
6.5
Connect compressor's wire
6.6
To energize the set (cabinet + compressor), connect input cabinet cord to the electric supply
and start button
Note:
1- Model MSV 12/100 is factory supplied with electric wire, without the plug. The user must
either install the plug directly to the start switch, or buy it according to local norms.
1.1-Select the plug, or the electric connection device, either according to the nominal voltage
specified in the motor's identification tag, or according to Table 2, page 8.
2- The energy supply network must not present voltage changes over ± 10%.
3- The voltage drop caused by the motor start must not be over 10%.
4- The compressor's acoustic cabinet, with vertical receiver volume of 30 liters, is factory
supplied with 115 or 230 (V) electric connection. If you need to change the voltage, check the
diagram placed inside the cabinet, which will guide you to change the voltage.
5- The thermal protector 19 is located inside the electric motor. If it goes off, it will re-start the
compressor after the temperature drops. The installation of protection fuses is necessary,
see Table 2, page 8.
6- Used fuse kind delayed-action.
- INSTALLATION EXPENSES ARE OF PURCHASER'S RESPONSIBILITY.
10
17
to the cabinet's internal plug.
16
.