The maximum admissible load on the tank is 350kg/m
First use up the goods that have been stored in the unit the longest before
adding new arrivals (food stock rotation);
Model H125:
The maximum admissible load on the shelves (version H125) is 160kg/m
avoid slipping of the goods on tilted shelves always use containment rails.
The shelves can be tilted in 2 different positions 0°; -10°

15.Defrosting and water drainage (Rif. 22)

The Coimbra 2 line of refrigeration cabinets is provided with a simple-stop defrost
system that stops the refrigeration cycle.
When the cabinet is defrosting, the temperature of the product on display will rise,
however, not above the limits established by law; when the defrosting cycle is over, the
system will rapidly return to its normal operating temperature.

15_1.Water drainage:

To evacuate the defrost water you must:
provide a drain to ground with a slight slope;
install the siphon supplied between the drain pipe of the cabinet and the connection
to ground.
hermetically seal the area of drainage to ground.
In this way, it is possible to avoid: bad odours inside the cabinet, dispersion of
refrigerated air, and the possible malfunction of the cabinet due to humidity.
Periodically check that hydraulic connections are perfectly efficient, contacting a
qualified installer.

16.Demisting and anti-condensation

The cabinet is provided with special hot cables to remove the presence of any mist or
condensation.
The cabinet is equipped with a demisting system in the outer bottom plate of the
cabinet.
DO NOT obstruct the fan air vents with goods, empty boxes, packages or other
(Rif. 17).
Ensure that the demisting fans are not clogged with goods displayed in the area in front
of the cabinet. (Rif. 17)

17.Lighting

Internal lighting of the unit is obtained through fluorescent lights.
The position of the light switch is shown in pos(Rif. 11).(A)

18.Light bulb replacement - specialized technician -

Before replacing the bulbs, unplug the cabinet from its power supply
To replace the lamps, proceed as follows:

18_1.Single light bulb (Rif. 18)

1 - Remove the polycarbonate cover (A);
2 - Turn the bulb by about 90° (until it clicks) and extract it;
3 - Replace the bulb with a new identical one.
4 - Reassemble the polycarbonate cover.
5 - Restore electrical power supply.

18_2.Light bulb assembly (Rif. 20)

1 - Force open with a PVC spring screw driver (B) as shown in the figure.
2 - Extract the light bulb assembly
3 - Unscrew the PVC springs from the lamp group
05060143 00 10/04/2013