Electrical specifications of the installation

MOD.
G-OEM-500
GM-OEM-500
GT-OEM-500
G-OEM-500
GM-OEM-500
GT-OEM-500
G-OEM-510
GM-OEM-510
GT-OEM-510
G-OEM-510
GM-OEM-510
GT-OEM-510
4.3.2

Voltage Configuration of the machine

The voltage configuration of the machine is stipulated on the nameplate. If the mains voltage supply
is not the same as that stipulated on the machine, there is a terminal box from which the different
voltage options can be configured (230V 1N~, 230V 3~ or 400V 3N~). Fig. 6, 7, 8
In the event of a change, the supplier must be notified to ensure that the machine's guarantee remains
valid. To access the terminal holder, undo the machine's cover.

4.4 Hydraulic connection

The new hoses supplied with the appliance should be used (do not reuse old hoses).
Before connecting the machine to the water supply, the water quality should be tested.
Recommended water quality:
Water temperature (T):
pH:
Impurities:
Chlorides:
Cl:
If the water hardness is more than 10 ⁰fH (French degrees), a descaler must be installed.
In addition to water quality, the pressure of the mains water supply must be considered. This is
important to ensure the machine operates correctly.
Required water pressure:
DYNAMIC
bar
PRESSURE
2
If the water pressure is higher than the recommended pressure, a pressure regulator must be mounted
at the output Fig. 2. If the mains water pressure is lower than the recommended pressure, a pressure
pump should be mounted at the mains water supply Fig. 3.
Fig. 2. Direct connection of water input hose.
Fig. 3. Pressure pump connection.
S → SHUT-OFF COCK
E → ELECTROVALVE
5
31mm in diameter and must be installed in accordance with AS/ NZ3500.2 (drainage) by means of coupled
connection to a DN50 or larger pipe
6
For Australia, watermark certified inlet hose and backflow prevention device. Must be installed in
accordance with AS/NZS3500.1 (water service supply) including installation of the supplied backflow
prevention device.
OPTIONS
(W/B/DD/F/SA)
(W/B/DD/F/SA) UK
(W/B/DD/F/SA)
(W/B/DD/F/SA) UK
ONLY AUTHORISED PERSONNEL may change the electrical
configuration. Users may not tamper with the machinery.
max. 60 ⁰C
6.5 - 7.5
Ø < 0.08 mm
max. 150 mg/l
0.2 - 0.5 mg/l
Min.
kPa
kg/cm
2
200
2,03
F → FILTER
B → ELECTRIC PRESSURE PUMP
POWER
MAX. ELECTRIC
SUPPLY
230V 1N~ 50/60Hz
230V 1N~ 50/60Hz
230V 1N~ 50/60Hz
230V 3~ 50/60Hz
400V 3N~ 50/60Hz
230V 1N~ 50/60Hz
230V 3~ 50/60Hz
400V 3N~ 50/60Hz
Total water hardness:
Conductivity:
psi
bar
29
4
5
46
AMP.
POWER
(A)
3,4 kW
15
2,8 kW
12,2 A
27 A
6,2 kW
16,7 A
10,7 A
27 A
6,2 kW
16,7 A
10,7 A
5 – 10 ⁰fH (French degrees)
7 – 14 ⁰eH (English degrees)
9 – 18 ⁰dH (German degrees)
400 - 1,000 µS/cm
Max.
kPa
kg/cm
2
400
4,07
58,01
H → WATER HOSE
NET
WEIGHT
54 kg
60 kg
psi
6