TIPS
During use, the following suggestions may be displayed on the
screen:
MESSAGE
CAUSE
Err1
Signal too weak
Err2
Signal too strong
Err3
Battery voltage too low
Err5
Wrong Pythagoras
measurement
Err6
The measuring range
has been exceeded
32
SOLUTION
Select a measurement point
with better reflection
capabilities
Select a measuring point with
less reflection capabilities
Replace the battery
Repeat the measurement by
making sure the length of the
hypotenuse is greater
than that of the legs.
TECHNICAL SPECIFICATIONS
Capacity *
Minimum reading
Measuring accuracy
Zoom function
Laser class
Laser type
Continuous measuring function
Area / volume measurement
Pythagoras functions
Sum and subtraction of measurements
Min / Max value
Stakeout
Self-timer
Calibration
Measurement memory with image
Video
Sound recording
Data transmission
End piece for diagonals
Inclinometer X and Y
Angle measurement
Storage capacity
Automatic shutdown laser
Automatic deactivation of the device
Rechargeable batteries
Battery life
Storage temperature
Operating temperature
Storage
Dimensions
* In non-optional conditions (strong light, backlight, characteristics and color of
the reflecting surface, exhausted batteries, etc.) the capacity may vary accordingly
120 m
0.05 m
± 2 mm
2x / 4x
II
635nm, <1mW
Yes
Yes
Yes, complete
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
+/- 90 °
16 GB
20 / 120s
100 / 300s
2-NiMh 1.2V 2400mAh
30,000 measurements
-20 ° C / 60 ° C
0 ° C / 40 ° C
RH85%
145x60x29 mm