Troubleshooting The Printer; Technical Data - Bosch BAT 131 Manual Original

Comprobadores de batarías
Ocultar thumbs Ver también para BAT 131:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

en
14 | BAT 131 | Maintenance & Troubleshooting
6.7

Troubleshooting the Printer

!
If the BAT 131 is not connected to a 12-volt battery
with at least 11.5 volts of power or the paper sensor
does not detect paper in the compartment during the
print process
Message
Action to be taken
BATTERY POWER TOO
To print, the tester must be proper-
LOW TO USE PRINTER.
ly connected to a vehicle battery ha-
CONNECT TO FULLY
ving at least 9 volts.
R Connect to a vehicle battery with
CHARGED BATTERY
11.50 TO 16.00V
R Make sure that the clamps are
R Check that both sides of the
CONNECT TO
Tester is not connected to the bat-
12V BATTERY
tery
LOW INTERNAL AA BAT-
Internal AA batteries are low and
TERIES. REPLACE AA
need to be replaced. See "Mainte-
BATTERIES SOON!
nance & Troubleshooting" section.
NON 12 VOLT SYSTEM
System being tested is not 12-volts.
DETECTED
PRINTER DOOR OPEN.
Check that the door covering the
CLOSE DOOR AND TRY
printer paper is properly closed and
TO PRINT AGAIN
latched.
PRINTER OUT OF PAPER
Printer is out of thermal paper.
R Verify that the paper is inserted
REPLACE WITH THERMAL
PRINTER PAPER.
2.5 IN. DIA. MAX
R Insert a new roll of paper.
2.25 IN. WIDE MAX
R Verify that the paper sensor is
QC DATA MEMORY FULL
QC mode memory is full. Select
PRINT RESULTS OR
QC mode from the Options Menu to
CLEAR MEMORY.
clear the memory.
6.8
Disposal
This BAT 131 is subject to European guideli-
nes 2002/96/EG (WEEE).
Old electrical and electronic devices, inclu-
dingcables and accessories or batteries must
be disposed of separate to household waste.
Please use the return and collection sys-
tems in place for disposal in your area.
Damage to the environment and hazards
to personal health are prevented by pro-
perly disposing of BAT 131.
|
1 689 989 132
2013-09-09
enough voltage to enable printing.
connected properly: red clamp to
the positive (+) terminal and the
black clamp to the negative (-) ter-
minal.
clamps are making contact with
the terminals.
correctly.
clean and undamaged
7.

Technical data

Function / Range
Function range
Accuracy range
Workplace-related
noise-emission value (Lpa)
7.1
Battery-Test and Voltmeter
Function / Range
Operating voltage
Operating current without printer
Entry range of Cold Start Current
Battery standards
7.2
Printer Paper
Function / Range
Maximum storage period by storage in
the dark in years
Maximum storage temperature
Maximum storage humidity
Value
0 °C – 50 °C
32 °F – 122 °F
0 °C – 40 °C
32 °F – 104 °F
< 70 dB(A)
Value
8 V – 16 V
0,4 A
50 A - 1550 A
CA, CCA, MCA,
DIN, EN, EN2
IEC, JIS, SAE
Value
< 5
30 °C
32 °F – 86 °F
<60 %
Robert Bosch GmbH

Capítulos

Tabla de contenido
loading

Tabla de contenido