*Date code 201811475B or later
**Date code 201536 or later
EnGLIsH
Batteries
Cat #
V
Ah
DC
DCB546
18/54
6.0/2.0
DCB547
18/54
9.0/3.0
DCB548
18/54
12.0/4.0
DCB181
18
1.5
DCB182
18
4.0
DCB183/B
18
2.0
DCB184/B
18
5.0
DCB185
18
1.3
DCB187
18
3.0
DCB189
18
4.0
*Date code 201811475B or later
**Date code 201536 or later
GENERAL POWER TOOL SAFETY WARNINGS
WARNING: Read all safety warnings, instructions,
illustrations and specifications provided with this
power tool. Failure to follow all instructions listed below
may result in electric shock, fire and/or serious injury.
SAVE ALL WARNINGS AND INSTRUCTIONS
FOR FUTURE REFERENCE.
The term "power tool" in the warnings refers to your mains-
operated (corded) power tool or battery-operated (cordless)
power tool.
1) Work Area Safety
a ) Keep work area clean and well lit. Cluttered or dark
areas invite accidents.
b ) Do not operate power tools in explosive
atmospheres, such as in the presence of flammable
liquids, gases or dust. Power tools create sparks which
may ignite the dust or fumes.
c ) Keep children and bystanders away while operating
a power tool. Distractions can cause you to lose control.
2) Electrical Safety
a ) Power tool plugs must match the outlet. Never
modify the plug in any way. Do not use any adapter
plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of
electric shock.
b ) Avoid body contact with earthed or grounded
surfaces such as pipes, radiators, ranges and
refrigerators. There is an increased risk of electric shock if
your body is earthed or grounded.
c ) Do not expose power tools to rain or wet conditions.
Water entering a power tool will increase the risk of
electric shock.
d ) Do not abuse the cord. Never use the cord for
carrying, pulling or unplugging the power tool. Keep
cord away from heat, oil, sharp edges or moving
parts. Damaged or entangled cords increase the risk of
electric shock.
26
Weight (kg) DCB104
DCB107 DCB112 DCB113 DCB115
1.05
60
270
1.46
75*
420
1.44
120
540
0.35
22
70
0.61
60/40**
185
0.40
30
90
0.62
75/50**
240
0.35
22
60
0.54
45
140
0.54
60
185
Chargers/Charge Times (Minutes)
DCB116
170
140
90
80
270
220
135*
110*
350
300
180
150
45
35
22
22
120
100
60
60/45** 60/40** 60/40**
60
50
30
30
150
120
75
75/60** 75/50** 75/50**
40
30
22
22
90
70
45
45
120
100
60
60
e ) When operating a power tool outdoors, use an
extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
f ) If operating a power tool in a damp location is
unavoidable, use a residual current device (RCD)
protected supply. Use of an RCD reduces the risk of
electric shock.
3) Personal Safety
a ) Stay alert, watch what you are doing and use
common sense when operating a power tool. Do not
use a power tool while you are tired or under the
influence of drugs, alcohol or medication. A moment
of inattention while operating power tools may result in
serious personal injury.
b ) Use personal protective equipment. Always wear
eye protection. Protective equipment such as dust mask,
non-skid safety shoes, hard hat or hearing protection used
for appropriate conditions will reduce personal injuries.
c ) Prevent unintentional starting. Ensure the switch
is in the off-position before connecting to power
source and/or battery pack, picking up or carrying
the tool. Carrying power tools with your finger on the
switch or energising power tools that have the switch on
invites accidents.
d ) Remove any adjusting key or wrench before turning
the power tool on. A wrench or a key left attached
to a rotating part of the power tool may result in
personal injury.
e ) Do not overreach. Keep proper footing and balance
at all times. This enables better control of the power tool
in unexpected situations.
f ) Dress properly. Do not wear loose clothing or
jewellery. Keep your hair and clothing away from
moving parts. Loose clothes, jewellery or long hair can be
caught in moving parts.
g ) If devices are provided for the connection of dust
extraction and collection facilities, ensure these are
connected and properly used. Use of dust collection
can reduce dust-related hazards.
DCB117
DCB118 DCB132 DCB119
40
60
90
X
60
75*
135*
X
80
120
180
X
22
22
22
45
60
120
30
30
30
60
75
150
22
22
22
X
45
45
45
90
60
60
60
120