Kohler K-527 Guia De Instalacion página 12

Ocultar thumbs Ver también para K-527:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Troubleshooting Table
Symptoms
Probable Cause
7.
Fluctuating or
A. Valve inlets may be
reduced flow
rate. Valve is
functioning
properly.
B. Fittings/Spray
C. Water outlet
D. Fluctuating supply
E. Water supply
8.
Blend
A. Fluctuating water
temperature
drift or
temperature
cycling.
B. Pressure difference
1143086-2-E
Recommended Action
A. Check the valve
blocked.
inlets for blockage or
debris. Clean the
inlet screens. Refer to
the "Clean the Inlet
Screens" section in
the Valve
Homeowners Guide.
B. Clean the spray faces
faces may be
and any screens in
blocked.
your fittings.
C. Check that the flow
pressure is low.
rate is at or above
the minimum rate
required. Refer to
"Specifications"
section in the Valve
Homeowners Guide.
D. Verify that the
pressure.
dynamic inlet
pressures are within
specifications. Refer
to "Specifications"
section in the Valve
Homeowners Guide.
E. Check if inlet water
temperatures are
temperatures are
not within the
within the
recommended
recommended range.
range.
A. Check the inlet
supply
temperature
temperature.
differentials and
verify they are
sufficient. Refer to
"Specifications"
section in the Valve
Homeowners Guide.
B. Install pressure
greater than 5 psi
regulators to bring
(34.5 kPa) between
the supplies within 5
the hot and cold
psi (34.5 kPa) of each
supply lines.
other.
12
Kohler Co.
Tabla de contenido
loading

Tabla de contenido