If you experience numbness, tingling, pain or whitening of the skin in your fi ngers or hands, stop using the tool, tell
your employer and consult a physician.
Where possible Support the weight of the tool in a stand, tensioner or balancer, because a lighter grip can then be used
to support the tool.

1.9 ADDITIONAL SAFETY INSTRUCTIONS FOR HYDRAULIC POWER TOOLS

The operating hydraulic supply must not exceed 550 bar (8000 PSI).
Oil under pressure can cause severe injury.
Do not fi t fl exible hydraulic hoses rated at less than 700 bar (10,000 PSI) working pressure at a fl ow rate of 2.73 l/min
3
(200 in
/min).
Never leave operating tool unattended. Disconnect hydraulic hose and electrical cable from the pump unit when tool is
not in use, before changing accessories or when making repairs.
Whipping hoses can cause severe injury. Always check for damaged or loose hoses and fi ttings.
Prior to use, inspect hydraulic hoses for damage, all hydraulic connections must be clean, fully engaged and tight
before operation. Do not drop heavy objects on hoses. A sharp impact may cause internal damage and lead to
premature hose failure.
Whenever universal twist couplings (claw couplings) are used, lock pins shall be installed and whipcheck safety cables
shall be used to safeguard against possible hose-to-tool or hose-to-hose connection failure.
DO NOT lift the placing tool by the hose or electrical cable. Always use the placing tool handle.
DO NOT pull or move the hydraulic pump unit using the hoses. Always use the pump unit handle or roll cage.
Keep dirt and foreign matter out of the hydraulic system of the tool as this will cause the tool to malfunction.
Use only clean oil and fi lling equipment.
Only recommended hydraulic fl uids may be used.
Power units require a free fl ow of air for cooling purposes and should therefore be positioned in a well ventilated area
free from hazardous fumes.
Maximum temperature of the hydraulic fl uid at the inlet is 110°C (230°F).